摘要
The endcap of time-of-flight (ETOF) detector in BES (Beijing Spectrometer) III is planned to be upgraded by using multi-gap resistive plate chambers (MRPCs) and the designed time resolution of the MRPCs is around 50 ps. Thus a time-zero (TO) detector needs to be built to offer a high quality reference time for the MRPCs beam test. So a TO detector is built using plastic scintillator tiles (BC420) to couple with four fast phototubes (PMTs, Hamamatsu H6533). The timing properties of the detector is studied by using a cosmic ray test and factors related to the time resolution, such as plastic scintillator size, readout mode and angle effects, are discussed. TO detector timing resolutions of -41-62 ps are achieved, which means that the TO detector can be used in the MRPC beam test.
The endcap of time-of-flight (ETOF) detector in BES (Beijing Spectrometer) III is planned to be upgraded by using multi-gap resistive plate chambers (MRPCs) and the designed time resolution of the MRPCs is around 50 ps. Thus a time-zero (TO) detector needs to be built to offer a high quality reference time for the MRPCs beam test. So a TO detector is built using plastic scintillator tiles (BC420) to couple with four fast phototubes (PMTs, Hamamatsu H6533). The timing properties of the detector is studied by using a cosmic ray test and factors related to the time resolution, such as plastic scintillator size, readout mode and angle effects, are discussed. TO detector timing resolutions of -41-62 ps are achieved, which means that the TO detector can be used in the MRPC beam test.
基金
Supported by State Key program of National Natural Science of China (10979003,10775181,10875140)
China PostdoctoralScience Foundation (20090460521)