Cosmic ray test for a T0 detector

Cosmic ray test for a T0 detector
原文传递
导出
摘要 The endcap of time-of-flight (ETOF) detector in BES (Beijing Spectrometer) III is planned to be upgraded by using multi-gap resistive plate chambers (MRPCs) and the designed time resolution of the MRPCs is around 50 ps. Thus a time-zero (TO) detector needs to be built to offer a high quality reference time for the MRPCs beam test. So a TO detector is built using plastic scintillator tiles (BC420) to couple with four fast phototubes (PMTs, Hamamatsu H6533). The timing properties of the detector is studied by using a cosmic ray test and factors related to the time resolution, such as plastic scintillator size, readout mode and angle effects, are discussed. TO detector timing resolutions of -41-62 ps are achieved, which means that the TO detector can be used in the MRPC beam test. The endcap of time-of-flight (ETOF) detector in BES (Beijing Spectrometer) III is planned to be upgraded by using multi-gap resistive plate chambers (MRPCs) and the designed time resolution of the MRPCs is around 50 ps. Thus a time-zero (TO) detector needs to be built to offer a high quality reference time for the MRPCs beam test. So a TO detector is built using plastic scintillator tiles (BC420) to couple with four fast phototubes (PMTs, Hamamatsu H6533). The timing properties of the detector is studied by using a cosmic ray test and factors related to the time resolution, such as plastic scintillator size, readout mode and angle effects, are discussed. TO detector timing resolutions of -41-62 ps are achieved, which means that the TO detector can be used in the MRPC beam test.
出处 《Chinese Physics C》 SCIE CAS CSCD 2011年第10期946-951,共6页 中国物理C(英文版)
基金 Supported by State Key program of National Natural Science of China (10979003,10775181,10875140) China PostdoctoralScience Foundation (20090460521)
关键词 TO plastic scintillator PMT MRPC ETOF TO, plastic scintillator, PMT, MRPC, ETOF
  • 相关文献

参考文献8

  • 1WANG Y et al. Nucl. Instrum. Methods A, 2010, 613:200.
  • 2Abbrescia M et al. Nucl. Instrum. Methods A, 2008, 593: 263-268.
  • 3AN S et al. HEP&:NP, 2005, 29(8): 777.
  • 4Fujii Y et al. Nucl. Instrum. Methods A, 1995, 366:282.
  • 5Bertoni R et al. Nucl. Instrum. Methods A, 2010, 615:22.
  • 6http:// jp. hamamatsu. com/products/sensor-etd/pd002 /pd394/H6533/index_en.html.
  • 7TAO Z et al. Nucl. Instrum. Methods A, 2009, 605: 282-292.
  • 8LI L et al. HEP&NP, 2007, 31(6): 577.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部