期刊文献+

某多塔楼大底盘工程隔震层设计 被引量:8

Design of seismic isolation layer below large base with multi-tower buildings
原文传递
导出
摘要 在9度设防区对某多塔楼围合式形成的大底盘多塔楼建筑进行隔震设计时,受建筑功能限制,不能在大底盘之上设置隔震层,而是采取在大底盘下设置,目前国内尚无先例。针对大底盘下设置隔震层遇到的特殊问题作了分析探讨,提出加强隔震层楼面刚度的措施,设定罕遇地震作用下隔震层楼板不屈服的性能目标,并进行了罕遇地震作用下围合中庭楼板破坏工况的验算,确保罕遇地震作用下隔震层不破坏。 In the design of a multi-tower building with large base in area of 9 degree seismic precautionary intensity,seismic isolation layer can not be applied above the large base due to the architectural function demand,while it was applied beneath the large base,and this is unprecedented in domestic.The special issues encountered in applying seismic isolation layer below the large base were analyzed.The rigidity of seismic isolation layer floor was enhanced,and unyieldingness performance objective of seismic isolation layer under rare earthquake action was presented.The damage cases calculation were carried out to ensure no seismic isolation layer damage under rare earthquake.
机构地区 云南省设计院
出处 《建筑结构》 CSCD 北大核心 2011年第10期42-46,67,共6页 Building Structure
关键词 大底盘 隔震层 刚度 弹性 large base seismic isolation layer rigidity elasticity
  • 相关文献

参考文献2

  • 1GB50011-2001建筑抗震设计规范[S].2008年版.北京:中国建筑工业出版社,2008.
  • 2CECS126:2001叠层橡胶支座隔震技术规程[S].北京:中国计划出版社,2001.