摘要
叙述核电站日常使用的电器安全保护设备——微机继电保护测试系统、串联谐振测试系统和高压开关机械特性测试系统的校准方案和方法。着重讨论这些校准方法中的技术难点,并对校准结果的不确定度进行了分析。这将有效地提高核电领域电器安全保护设备的可靠性和准确性,从而确保核电的运营安全。
This article describes the calibration program and method of the electrical safety protective equipment in nuclear power plant daily using, such as computer relay test systems, series resonance test systems and high-voltage switching mechanical testing system. Author focuses on the technical difficulties in the calibration method, and the uncertainty analysis of calibration results. This will effectively increase the field of nuclear power equipment, electrical safety to protect the reliability and accuracy to ensure the operational safety of nuclear power.
出处
《上海计量测试》
2011年第5期21-24,共4页
Shanghai Measurement and Testing
基金
国家质检总局科技计划项目(2009QK111)
关键词
核电安全设备
校准方法
技术难点
不确定度分析
nuclear safety protection equipment
calibration method
technical difficulties
uncertainty analysis