期刊文献+

对比剂团注跟踪技术在糖尿病患者下肢血管病变中的应用 被引量:1

Application of bolus chasing technology in lower limb artery angiography of diabetes mellitus
下载PDF
导出
摘要 目的比较对比剂团注跟踪造影技术(BCA)与数字减影血管造影法(DSA)在下肢动脉造影中的临床应用价值。方法回顾性分析我院12例采用BCA及20例采用DSA行下肢动脉造影的患者的X线吸收剂量、对比剂用量、造影完成时间,并对BCA图像质量进行分级评价。结果采用BCA和DSA法完成单侧下肢动脉造影患者的X线吸收剂量分别为(12.3±2.4)、(23.4±2.5)mGy,对比剂用量分别为(20±5)和(30±4)mL,造影完成时间分别为(4.9±1.5)、(12.3±0.9)min,差异均具有统计学意义(P<0.05)。结论采用BCA进行下肢动脉造影较传统DSA法检查具有使用对比剂少、检查时间短、图像直观等优点,且能一次性准确显示全下肢血管的解剖情况,值得临床进一步推广应用。 Objective To study the value of bolus chasing technology in lower limb artery angiography and its quality control by comparing with static digital subtraction angiography (DSA). Methods Twelve cases underwent lower limb artery angiography by using bolus chasing technology, and 20 eases by using traditional static DSA segmentation method. The radiation dose, the dosage of contrast agents, completion time and image quality were compared between the two groups. Results The radiation dose were (12.3±2.4) mGy (bolus chasing group) and (23.4±2.5) mGy (traditional DSA segmentation method) respectively. The dosage of contrast agents were (20±5) mL and (30±4) mL respectively. The completion time were (4.9±1.5) rain and (12.3±0.9) min. Conelusion Bolus chasing technology is a good method in lower limb artery angiography with a low dose of radiation, a short time of examination and good quality of imaging.
出处 《实用医技杂志》 2011年第10期1016-1018,共3页 Journal of Practical Medical Techniques
关键词 血管造影术 数字减影 糖尿病血管病变 下肢 Angiography, digital subtraction Diabetic angiopathies Lower extremity
  • 相关文献

参考文献10

二级参考文献36

  • 1余宏建,曲路,魏秋花,韩志华.DSA子宫输卵管造影诊治不孕症的价值探讨[J].现代医用影像学,2006,15(4):152-154. 被引量:8
  • 2Cronbcrg CN,Sji~berg S,Atbrechtsson U,et al. Peripheral arterial disease:contrast enhanced 3D MR angiography of the lower leg and foot compared with conventional angiography. Acta Radiol, 2003,44(1):59-66.
  • 3Ruehm SG, Nanz D, Baumann A, et al. 3D contrast-enhanced MR angiography of the run-off vessel:value of image subtraction. Magn Imaging,2001,13:402-411.
  • 4Snidow JJ,Johnson MS, Harris VJ. Three dimensional gadolinium-enhanced magnetic MR angiography for aorto-iliacin flow assessment plus renal artery screening in a single breath hold.Radiology, 1996,198:725-729.
  • 5Poon E,Yucel EK,Pagan-Marin H,et al. lliac artey stenosis measurements: compare of two dimensional time of flight and three dimensional dynamic gadolinium enhanced MR angiography. AJR, 1997,169 (4) : 1139-1144.
  • 6Dorweiler B,Neufang A,Kreitner KF,et al. Magnetic resonance angiography unmasks reliable target vessels for p~dal bypass grafting in patients with diabetes mellitus. Vasc Surg, 2002,35(4): 766-772.
  • 7Krause UJ,Pabst T,Kenn W,et al. Time-resolved contrast-enhanced magnetic resonance angiography of the lower extremity. Angiology, 2004,55(2): 119-125.
  • 8Meckel S,Mekle R,Taschner C,et al. Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience.Neuroradiology, 2006,48(5):291-299.
  • 9Krause U, Kroencke T,Spielhaupter E,et al. Contrast-enhanced magnetic resonance angiography of the lower extremities:standard-dose vs high-dose gadodiamide injection. Magn Reson Imaging, 2005,21(4):449-454.
  • 10Eason SL,Peterson NJ.Diabetes Mellitus,smoking,and the risk for asymptomatic peripheral arterial disease:whom should we screen?[J].J Am Borad Fam Pract,2005,18:355.