期刊文献+

无锡鸿山遗址博物馆空调系统设计

Air conditioning system design of Wuxi Hongshan Ruins Museum
下载PDF
导出
摘要 介绍了该博物馆的空调系统设计。由于建筑所处位置较开阔,且建筑本身不高,使得空调设备与建筑的协调成为本工程的难点。采用水源热泵作为冷热源,解决了建筑与空调室外设备的协调问题,同时达到了节能的目的;末端为全空气系统和风机盘管加新风系统,简洁实用,控制灵活。地上建筑相对独立,空调管道通过地下管廊连接,很好地解决了室内装饰效果与空调设备之间的矛盾,保证建筑的室内美观要求。 Presents the air conditioning system design of the museum.Located in an open ground and with relatively smaller height made it difficult to coordinate the outdoor air conditioning equipment and architectural effect of the project.By taking water-source heat pump as cold and heat source of air conditioning system,solves the coordination problem and reduces energy consumption.It is simple,practical and flexible to control to use the all-air system and fan coil unit plus fresh air system.The building above the ground level is relative independent,while the air conditioning ducts are laid through a huge underground pipe gallery,the contradiction between interior decoration and air conditioning equipment is well solved,and the indoor artistic requirement is satisfied.
作者 王加 劳逸民
出处 《暖通空调》 北大核心 2011年第10期38-41,共4页 Heating Ventilating & Air Conditioning
关键词 遗址博物馆 空调设计 水源热泵 管廊 ruins museum air conditioning design water-source heat pump pipe gallery