期刊文献+

高效液相色谱分离-在线光化学衍生/荧光光谱法测定5种水溶性维生素的研究 被引量:4

Simultaneous Determination of 5 Water-soluble Vitamins by HPLC with On-line Photochemical Derivatization and Fluorescence Detection
下载PDF
导出
摘要 建立了高效液相色谱分离-在线光化学衍生/荧光光谱法测定水溶性维生素烟酸(NIA)、烟酰胺(NIC)、B1、B12及B2的新方法。以含有0.018 mol/L三乙胺、0.002 mol/L庚烷磺酸钠的0.05 mol/L磷酸盐缓冲液(A相,pH 5.8)和甲醇(B相)为流动相(85∶15),等度洗脱分离5种水溶性维生素;将自制的程序控制时间/光强光化学反应器接在二极管阵列检测器(DAD)和荧光检测器(FLD)之间,进行光化学衍生。优化了光化学衍生的条件,并用于复合维生素片中水溶性维生素的测定。在优化实验条件下,5种水溶性维生素的线性范围分别为:NIA、NIC为0.1~10.0 mg/L,B1、B12为0.2~20.0 mg/L,B2为0.01~1.0 mg/L,方法的检出限(LOD,3σ)和定量下限(LOQ,10σ)分别为1.5~25.4μg/L和5.0~84.7μg/L,优于传统的高效液相色谱分离/二极管阵列检测方法。方法的相对标准偏差(n=7)不大于7.8%,样品的加标回收率为98%~103%。 A high performance liquid chromatographic (HPLC) method using on-line photochemical derivatization and fluorescence detection was developed for the simuhaneous determination of nicotinic acid(NIA), nieotinamide ( NIC), thiamine hydrochloride ( B, ), riboflavin ( B2 ) and cyanocobalamin(B12). A self-buih time/energy programmed photochemical reactor (PCR) with an ultraviolet mercury lamp was installed between the diode-array detector(DAD) and fluorescence detector(FLD) to convert the non- or weakly fluorescent vitamins into fluorescence compounds. The separation of NIA, NIC, B1, B12 and B2 was achieved within 12 min using 0.05 mol/L phosphate buffer(pH 5.8) - 0. 018 mol/L triethylamine - 0. 002 mol/L sodium heptane sulfonate (A) and methanol(B) as mobile phase by isocratic elution(A : B, 85 : 15). The separation and photochemical derivatization conditions were optimized. Under the optimal conditions, the calibration curves of five vitamins were linear in the range of 0. 1 - 10.0 mg/L for NIA and NIC, 0.2 - 20. 0 mg/L for B1 and B12, 0.01 - 1.0 mg/L for B2 with correlation coefficient (r) more than 0. 996. The limits of detection (LOD, 3σ) ranged front 1.5 μg/L to 25.4 μg/L and the limits of quantitation(LOQs, 10σ) were 5.0 -84.7 μg/L, which were better than those of the traditional HPLC/DAD method. The relative standard deviations(RSDs, n = 7) were not more than 7.8% and the spiked recoveries were between 98% and 103%. The developed method was successfully applied in the determination of vitamins NIC, B1 and B2 in muhivitamin tablets.
出处 《分析测试学报》 CAS CSCD 北大核心 2011年第10期1100-1106,共7页 Journal of Instrumental Analysis
基金 University research grant from Agilent Technologies Foundation USA
关键词 水溶性维生素 光化学衍生 荧光检测 高效液相色谱 water-soluble vitamins photochemical derivatization fluorescence detection high performance liquid chromatography
  • 相关文献

参考文献33

  • 1Diaz A N, Paniagua A G, Sanchez F G. J. Chromatogr. A, 1993, 655 (1) : 39 -43.
  • 2Bhushan R, Parshad V. Biomed. Chromatogr. , 1994, 8(4) : 196 - 198.
  • 3Bhushan R, Parshad V. J. Liq. Chromatogr. Relat. Technol. , 1999, 22(10) . 1607 - 1623.
  • 4Jegle U. J. Chromatogr. A, 1993, 652(2) : 495 -501.
  • 5曹志广,丁祥欢,叶建农.维生素片中水溶性维生素的毛细管电泳-电化学法测定[J].分析测试学报,1999,18(5):57-59. 被引量:32
  • 6Fotsing L, Boulanger B, Chiap P, Fillet M, Hubert P, Crommen J. Biomed. Chromatogr., 2000, 14(1): 10-11.
  • 7Fujiwara S, Iwase S, Honda S. J. Chromatogr. , 1988, 447(1) : 133 -140.
  • 8Nishi H, Tsumagari N, Kakimoto T, Terabe S. J. Chromatogr. , 1989, 465(3) : 331 -343.
  • 9李来生,张江华.反相高效液相色谱法测定食品中水溶性维生素的含量[J].分析测试学报,1997,16(3):25-28. 被引量:27
  • 10Moreno P, Salvado V. J. Chromatogr. A, 2000, 870(1/2) : 207 -215.

二级参考文献38

共引文献259

同被引文献23

引证文献4

二级引证文献29

相关作者