摘要 研究了基于响应量转换法测量浑浊介质中成分浓度方法的可行性,以Intralipid为研究对象,通过(monte carlo,MC)结合反向倍增法(inverse adding doubling,IAD)算法的模拟实验和双积分球系统结合IAD算法实验的方法,验证了IAD算法和双积分球系统提取散射信息的有效性,并进一步考察了散射系数预测成分浓度的可行性。结果表明,基于响应量转换法测量浑浊介质中成分的浓度有效可行,用散射系数与浓度的线性关系模型预测浓度的相对误差保持在10%以内。 The present paper primarily studied the feasibility of the measurement of composition concentration in turbid media using response variable transform(RVT) method.With intralipid as the subject,the simulation of Monte Carlo in conjunction with the IAD algorithm and the experiment of double-integrating-sphere system combined with the IAD algorithm were conducted to verify the effectiveness to extract the scattering information.Furthermore,for the feasibility of the scattering coefficient to predict the concentration of intralipid,the results showed that measuring the component concentration in turbid media by means of RVT method is effective and feasible,and the relative error to predict the concentration with the linear relationship between scattering coefficient and concentration of intralipid is less than 10%.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2011年第11期3074-3077,共4页 Spectroscopy and Spectral Analysis
基金 国家自然科学基金项目(60938002 30900275) 高等学校博士学科点专项科研基金项目(20090032120064)资助
关键词 响应量转换 双积分球系统 反向倍增法 散射 Response variable transform Double-integrating-sphere system Inverse adding doubling Scattering
  • 相关文献

参考文献7

  • 1LU Wan-zhen (陆婉珍).Modern Near Infrared Spectroscopy Analytical Technology-Second Edition(现代近红外光谱分析技术,第2版).Beijing: China Petrochemical Press(北京:中国石化出版社),2006.35.
  • 2Wang Lihong,Jacques Steven L,Zheng Liqiong.Computer Methods and Programs in Biomedicine,1995,47: 131.
  • 3Prahl S A.Optical Property Measurements Using the Inverse Adding-Doubling Progam.Oregon Medical Laser Center,Portland,2007.
  • 4Pickering J W,Prahl S A,Van Wieringen N,et al.Applied Optics,1993,32(4): 399.
  • 5Van Staveren H J,Moes C J M,Van Marle J,et al.Applied Optics,1991,30: 4507.
  • 6Rene Michels,Florian Foschum,Alwin Kienle.Optical Express,2008,16(8): 5907.
  • 7李晨曦,赵会娟,王秋殷,宋扬,徐可欣.基于双积分球和锁相放大测量的近红外多波长光学参量测量系统的研究[J].光子学报,2009,38(7):1811-1815. 被引量:4

二级参考文献1