期刊文献+

2500t/d生产线4.5MW余热发电调试与改造 被引量:1

Commissioning and alteration of 4.5MW waste heat power generation system of a 2500t/d clinker production line
下载PDF
导出
摘要 华润水泥(阳春)有限公司2500t/d熟料生产线配套建设了4.5MW的余热发电机组。分析介绍了该机组调试运行中出现的锅炉给水系统、电气励磁系统及DCS系统的问题及处理方法;同时,对提升系统发电量和节电、节水措施也作了详细介绍。 China Resources Cement (Yangchun) Co.,Ltd. constructed a 4.SMW waste heat power generation unit for their 2500t/d clinker production line. And the problems of water supply system, electric magnetization system and DCS system in commissioning of the power generation unit were analysed and the measures were introduced as well as that of increasing power generation and saving energy and water.
出处 《水泥工程》 CAS 2011年第5期84-86,共3页 Cement Engineering
关键词 余热发电 锅炉 省煤器 安全阀 DCS系统 接地故障 节电 节水 waste heat power generation boiler economizer safe valve DCS system earthing fault save power save water
  • 相关文献