期刊文献+

絮凝-Fenton氧化处理E段漂白废水的研究 被引量:3

A study on treatment of E stage effluent by flocculation-Fenton oxidation
下载PDF
导出
摘要 采用絮凝-Fenton氧化处理E段漂白废水。通过正交实验确定了最佳操作参数。Al2(SO4)3-Fenton氧化配合处理E段漂白废水的最佳操作条件为:Al2(SO4)3用量0.6g/L,氧化反应的pH值为5,H2O2用量1.0g/L,FeSO4用量0.8g/L,在此条件下废水COD的去除率可达90.64%。CPAM-Fenton氧化配合处理E段漂白废水的最佳操作条件为:CPAM用量0.8mg/L,氧化反应pH值6,H2O2用量1.5g/L,FeSO4用量1.2g/L,在此条件下废水COD的去除率可达82.43%。 The E stage effluent from bleaching process was treated by flocculation-Fenton oxidation, its best conditions was determined through orthogonal experiments. The results show that the optimum treating conditions of Al2(SO4)3-Fenton oxidation system are as follows: Al2(SO4)3 dosage 0.6g/L, oxidation pH 5, H2O2 dosage 1.0g/L, FeSO4 dosage 0.8g/L, with the CODCr removal rate reaching 90.64%. The optimum treating conditions of CPAM-Fenton oxidation system are as follows: CPAM dosage 0.8mg/L, oxidation pH 6, H2O2 dosage 1.5g/L, FeSO4 dosage 1.2g/L, with CODCr removal rate reaching 82.43%.
出处 《中华纸业》 CAS 北大核心 2011年第20期40-42,共3页 China Pulp & Paper Industry
关键词 E段漂白废水 絮凝-Fenton氧化 红外光谱 E stage effluent flocculation-Fenton oxidation FTIR spectrum
  • 相关文献

参考文献4

二级参考文献29

共引文献117

同被引文献52

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部