期刊文献+

Investigation of Capacitively Coupled Argon Plasma Driven by Dual-Frequency with Different Frequency Configurations 被引量:1

Investigation of Capacitively Coupled Argon Plasma Driven by Dual-Frequency with Different Frequency Configurations
下载PDF
导出
摘要 Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are investigated by using a floating double electrical probe and optical emission spectroscopy (OES). It is shown that in the DF-CCPs, the electron temperature Te decreases with the increase in exciting frequency, while the onset of 2 MHz induces a sudden increase in Te and the electron density increases basically with the increase in low frequency (LF) power. The intensity of 750.4 nm emission line increases with the LF power in the case of 13.56/2 MHz, while different tendencies of line intensity with the LF power appear for other configurations. The reason for this is also discussed. Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are investigated by using a floating double electrical probe and optical emission spectroscopy (OES). It is shown that in the DF-CCPs, the electron temperature Te decreases with the increase in exciting frequency, while the onset of 2 MHz induces a sudden increase in Te and the electron density increases basically with the increase in low frequency (LF) power. The intensity of 750.4 nm emission line increases with the LF power in the case of 13.56/2 MHz, while different tendencies of line intensity with the LF power appear for other configurations. The reason for this is also discussed.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第5期571-574,共4页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China (Nos. 10635010, 10775103)
关键词 dual-frequency capacitively coupled plasma double probe optical emission spectroscopy dual-frequency capacitively coupled plasma, double probe, optical emission spectroscopy
  • 相关文献

参考文献27

  • 1Lieberman M A, Lichtenberg A J. 2005, Principles of Plasma Discharges and Materials Processing. Wiley, Hoboken, New Jersey. p.14, 197, 333.
  • 2Goto H H, Lowe H D, Ohmi T. 1992, J. Vac. Sci. Technol. A, 10:3048.
  • 3Boyle P C, Ellingboe A R, Turner M M. 2004, J. Phys. D: Appl. Phys., 37:697.
  • 4Kim H C, Lee J K and Shon J W. 2003, Phys. Plasmas, 10:4545.
  • 5Jiang W, Mao M and Wang Y N. 2006, Phys. Plasmas, 13:113502.
  • 6Wang S, Xu X and Wang Y N. 2007, Phys. Plasmas, 14:113501.
  • 7Xu Y J, Ye C, Huang X J, et al. 2008, Chin. Phys. Lett., 25:2942.
  • 8Yuan Q H, Xin Y, Yin G Q, et al. 2008, J. Phys. D: Appl. Phys., 41:205209.
  • 9Huang X J, Xin Y, Zhang J, et al. 2009, Chin. Phys. Lett., 26:055202.
  • 10Ahn S K and Chang H Y. 2009, Appl. Phys. Lett., 95: 111502.

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...