期刊文献+

X型板式换热器的数值模拟结构热应力分析 被引量:2

Thermal Stress Analysis for X-shaped Plate Heat Exchangers with Three-dimensional Structure
下载PDF
导出
摘要 应用Ansys对X型板式换热器进行热应力的数值模拟结构分析,模拟采用三板双通道形式、接缝处分别为辊焊焊接形式的模型,在模型的最外壁分别加以位移为0载荷,以固定板片模型为静态形式。在上下两个通道口分别给与温度载荷进行热分析,并应用间接热固耦合法进行热应力分析。研究结果表明:在板身区域,热应力均匀且非主要强应力区域;在焊接处及板与板之间的夹角处为热应力集中且易破坏区域。 Ansys was applied to simulate and analyze the thermal stress of X-shaped plate heat exchangers;in simulation, a three-plate dual-channel form was employed and roller welding model was established for roller seams ; at the model' s utmost outerwall, a load with zero displacement was made and a fixed plate model was regarded as static form. At upper and lower openings, a temperature load was given to benefit thermal stress analysis. The results show that over the plate body, the thermal stress distributes uniformly, and the thermal stress only concentrates at the welds and the intersection angle between plates and undermines them.
出处 《化工机械》 CAS 2011年第5期591-593,642,共4页 Chemical Engineering & Machinery
关键词 X型板式换热器 ANSYS 热应力 X-shape plate heat exchanger, Ansys, thermal stress
  • 相关文献

参考文献5

二级参考文献15

  • 1胡锡文,林兴华.管壳式换热器管板的有限元分析[J].压力容器,2004,21(10):26-28. 被引量:27
  • 2杨宏悦,蔡纪宁,张秋翔,李双喜.大型固定管板式换热器管板稳态温度场及热应力场分析[J].化工设备与管道,2006,43(1):11-15. 被引量:25
  • 3国家标准GB150-1998.钢制压力容器
  • 4王福军.计算流体动力学分析:CFD软件应用及原理.北京:清华大学出版社.2004
  • 5Mark Filipiak. Mesh Generation. Edinburgh Parallel Computing Center. The University of Edinburgh. Versionl. O, 1996
  • 6Suhas V Patankar. Numerical Heat Transfer and Fluid Flow . New York:Hemisphere Publishing Corporation. 1979
  • 7梁泉水.预应力换热器的分析与实验研究:[硕士论文].广州:华南理工大学,2006
  • 8杨崇麟.板式换热器工程设计手册[M].北京:机械工业出版社,1988.
  • 9Garrett-Price B A. Fouling of Heat Exchangers[M]. New Jersey : Noyes Publications, 1985.
  • 10尾花英朗.热交换器设计手册[M].北京:烃加工出版社,1966.