中央空调冬季冷却塔供冷节能实践 被引量:2

Energy saving analysis of cooling tower for supplying cooling water for central air-conditioning in winter
下载PDF
导出
摘要 对于全年供冷的中央空调系统,冬季采用冷却塔代替冷水机组为空调供冷水,是非常理想的节能措施之一。本文根据不同工程实践,分析了不同冷却水系统的可行方案及注意事项,可供设计及管理人员参考。 Cooling water supply for the central air-conditioning by the cooling tower instead of the chiller in winter is one of the ideal energy saving methods for the air-conditioning system which provide whole-yearly cold supply. According to different engineering practice, the feasible options of different cooling water systems were analyzed and the key points were set forward which need to be take into consideration by the designers and managers.
出处 《制冷技术》 2011年第2期45-48,共4页 Chinese Journal of Refrigeration Technology
关键词 中央空调 冷却塔 冬季供冷 节能 central air-conditioning cooling tower winter cold supply energy saving