摘要
结合国内外标准规范的规定和对比,分析了仓库场所火灾危险等级的划分方式,比较了2种设计方法的适用范围,并以具体工程案例为基础,提出了仓库采用自动喷水灭火系统的一些设置要求和建议。
Combined with the regulations and contrast of domestic and international standards,it's analyzed the classification means of storehouse fire danger.Compared two kinds of design scope and based on specific project case,several setting requirements and recommendations of storehouse with auto-sprinkler system were proposed as the reference for designers and fire supervision departments.
出处
《消防科学与技术》
CAS
北大核心
2011年第10期931-933,共3页
Fire Science and Technology
关键词
仓库
自动喷水灭火系统
货架内喷头
storehouse
auto-sprinkler system
shower nozzle inside shelves