高度近视有晶状体眼后房型人工矫正晶状体植入术后视觉质量的临床评价 被引量:7

Clinical evaluation of visual quality following implantation of posterior chamber phakic intraocular corrective lens for high myopia
下载PDF
导出
摘要 背景有晶状体眼后房型人工矫正晶状体(ICL)植入术是矫正高度近视的手术方法之一,与准分子激光角膜原位磨镶术(LASIK)不同的是,该术式保留了角膜与晶状体像差固有的匹配关系,但术后视觉质量是患者和医师较为关注的问题。目的探讨ICL植入术矫正高度近视术后视觉质量的变化。方法对高度近视患者42例84眼行ICL植入术,于术后1d、1个月和6个月复查裸眼视力、最佳矫正视力(BCVA)、屈光状态、波前像差、对比敏感度以及调节力并与术前进行比较。结果采用前瞻性病例观察试验设计。本组患者术前视力均〈0.3,术后各随访时问点裸眼视力和BCVA均〉0.3,明显好于术前。术后各时间点间视力增加的眼数差异无统计学意义(x2=10.70,P〉0.05)。本组患者术前平均等效球径屈光度为(-15.384-1.03)D,术后1d平均等效球镜屈光度为(+0.55±0.06)D,术后1个月平均等效球镜屈光度为(-1.22±0.09)D,术后6个月平均等效球镜屈光度为(-0.68±0.06)D,各时间点比较等效球镜屈光度的差异有统计学意义(F=16559.90,P〈0.01);术眼术前平均波前总像差为11.00±0.25,术后6个月平均总像差为2.21±0.56,其中术前和术后6个月高阶像差分别为0.43±0.05和0.47±0.04,差异无统计学意义(t=1.65,P=0.10)。明视和暗视状态下术后各空间频率的对比敏感度和眩光敏感度与术前比较均有增高,手术前后各时间点的对比敏感度和眩光敏感度差异有统计学意义(P〈0.05);术后1个月和6个月时屈光度〈-16D组术眼调节力较术前明显增加(术前:2.75±1.20,术后1个月:5.75±1.44;术后6个月:6.00±1.52),差异均有统计学意义(F=1597.70,P〈0.05);而屈光度〉-16D组手术前后调节力的变化差异无统计学意义(F=2.67,P〉0.05)。结论ICL植入术矫正高度近视后患者的视觉质量较术前明显改善,但远期疗效及安全性尚需进一步观察。 Background hnplantation of phakic posterior chamber intraocular corrective lens (ICL) is a new choice for correction of high myopia. Different from laser assisted in situ keratomileusis, implantation of phakic posterior chamber ICL will allow the good imaging quality because it remaines the matched relationship between cornea and lens. But its visual quality after operation is concerned by patient and ophthalmologists. Objective This study was to observe the effectiveness of implantation of posterior chamber phakic ICL on visual quality in patients with high myopia. Methods Eighty-four high myopia eyes of 42 patients accepted implantation of posterior chamber phakic ICL and follow-up of 6-month duration. The visual acuity, refractive status, wavefront, contrast sensitivity and accommodation were examined and compared before and after surgery. This clinical study complied with Declaration of Helsinki. The written informed consent was obtained from each patient before operation. Results A prospective observational trial design was used. The uncorrected visual acuity and best corrected visual acuity after operation were better than preoperative ones in all of the patients. The eye numbers of 〉0.3 were increased after operation in eomparison with before operation with a stable result among 1 day, 1 month and 6 months after surgery (X2 = 10.70, P〉0.05 ). Spherical equivalent refraction was ( -15.38±1.03 ) D before surgery and ( +0.55±0.06 ) at 1 day, (-1.22±0.09) D at 1 month and ( -0.68±0.06 ) D after 6 months, showing a significant difference among them ( F = 16 559.90, P 〈 0.05 ). Total aberrations and higher-order aberrations were 11.00±0.25 and 0.43±0.05 before surgery,the wavefront aberrations were 2.21±0.56 and 0.47±0.04 at 6 months after surgery with significant difference(t = 1.65, P = 0. 10). Each spatial frequency contrast sensitivity and glare sensitivity on photopic and scotopic conditions in postoperation were higher compared with the preoperative ( P〈0.05). The accommodation in 1 month and 6 months after surgery was greater than that of preoperative in the patients 〈-16 D (preoperation:2.75±1.20 ;postoperation 1 month:5.75±1.44, postoperation 6 months:6.00±1.52) (P〈0.05) ,however,in the 〉-16 D group, no considerably change in accommodation was seen after surgery ( F= 1597.70, P〈0.05 ). No significant difference was found in accommodation between before and after surgery in 〉-16 D group (F= 2.67, P〉0. 05 ). Conclusions Visual quality of high myopia is obviously improved after implantation of posterior chamber phakic ICL,but its long-term outcome is need to further study.
出处 《中华实验眼科杂志》 CAS CSCD 北大核心 2011年第10期926-930,共5页 Chinese Journal Of Experimental Ophthalmology
关键词 高度近视 有晶状体眼 后房型人工矫正晶状体 视觉质量 High myopia Phakie eye Posterior chamber phakie introeular correetive lens Visual quality
  • 相关文献

同被引文献45

  • 1俞阿勇,林振德.有晶状体眼后房型人工晶状体植入术矫治中高度近视眼[J].中华眼科杂志,2005,41(6):572-576. 被引量:32
  • 2沈晔,周天安,杜持新,汪阳,夏建华.有晶状体眼后房型人工晶状体植入矫正高度近视的临床评价[J].中华眼科杂志,2007,43(11):1000-1004. 被引量:49
  • 3Binder PS, Trattler WB. Evaluation of a risk factor scoring system for corneal ectasia after LASIK in eyes with normal topography [ J ]. J Refract Surg,2010,26 (4) :241-250.
  • 4Tsiklis NS,Kymionis GD, Karp CL, et al. Nine-year follow-up of a posterior chamber phakic IOL in one eye and LASIK in the fellow eye of the same patient[ J]. J Refract Surg,2007,23 (9) :935-937.
  • 5于玮,王丽双,胡桂荣.后房型有晶体眼人工晶体植入术治疗超高度近视眼的护理[J].中外健康文摘,2013(15):57-59.
  • 6Sanders DR, Vukich JA, Doney K, et al.U.S.Food and Drug Administration clinical trial of the implantable contact lens for moderate to high myopia[J].Ophthalmology,2003,110:255-266.
  • 7Sanders DR, Doney K, Poco M, et al.United States Food and Drug Administration clinical trial of the implantable collamer lens (ICL) for moderate to high myopia: three-year follow-up[J].Ophthalmology,2004,111:1683-1692.
  • 8Mangione CM, Lee PP, Gutierrez PR.Development of the 25-item national eye institute visual function questionnaire[J].Arch Ophthalmol,2001,119:1050-1058.
  • 9Kim DS, Narvaez J, Krassin J.Comparison of the VISX wavescan and NIDEK OPD-scan aberrometers[J].J Refract Surg,2009, 25:429-434.
  • 10Pérez-Vives C1, Domínguez-Vicent A, Ferrer-Blasco T, et al.Optical quality of the visian implantable collamer lens for different refractive powers[J].Graefes Arch Clin Exp Ophthalmol,2013,251:1423-1429.

引证文献7

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部