摘要
通过几年来在浮法玻璃生产中对2条生产线的流道底过桥砖断裂现象的对比观察,结合理论原理、数据分析,找到影响流道过桥砖断裂的原因和有效地保护措施及改进方法,在保证生产安全的同时,对熔窑烘烤与锡槽升温具有指导意义。
The breaking causes and effective safeguard measures of over-bridge block at the bottom of flow passage of float glass furnace were discussed based on paired observation, investigation and data analysis in recent years . These practice will have directive significance to heat-up of furnace and tin-bath.
出处
《玻璃》
2011年第10期15-17,共3页
Glass
关键词
浮法玻璃
流道
过桥砖
断裂
保护
float glass , flow passage , over-bridge block ,breaking, protection