摘要
针对低温热水地热采暖卫生间渗漏问题进行了分析,从楼板密实性、防水层施工、填充层及找平层处理等方面入手阐述了渗漏的原因,提出了相应的预防措施,并指出卫生间的防水处理应做好堵和导两方面,注意施工过程中质量控制。
The paper analyzes the leakage problems in the low-temperature water geothermal heating toilets,illustrates the reasons for the leakage from the floor compactness,the construction of the waterproof layer,the packing layer,and the treatment of the leveling blanket,points out the respective prevention measures,and points out the waterproof treatment of the toilets can do well in the blocking and the direction,and pay attention to the quality control in the construction process.
出处
《山西建筑》
2011年第32期116-117,共2页
Shanxi Architecture
关键词
地热采暖
卫生间
防水处理
地面坡度
geothermal heating
toilet
waterproof treatment
slope of ground