期刊文献+

低温热水地热采暖卫生间渗漏原因及防治

On reasons for leakage in low-temperature water geothermal heating toilets and its prevention
下载PDF
导出
摘要 针对低温热水地热采暖卫生间渗漏问题进行了分析,从楼板密实性、防水层施工、填充层及找平层处理等方面入手阐述了渗漏的原因,提出了相应的预防措施,并指出卫生间的防水处理应做好堵和导两方面,注意施工过程中质量控制。 The paper analyzes the leakage problems in the low-temperature water geothermal heating toilets,illustrates the reasons for the leakage from the floor compactness,the construction of the waterproof layer,the packing layer,and the treatment of the leveling blanket,points out the respective prevention measures,and points out the waterproof treatment of the toilets can do well in the blocking and the direction,and pay attention to the quality control in the construction process.
作者 张芳莲
出处 《山西建筑》 2011年第32期116-117,共2页 Shanxi Architecture
关键词 地热采暖 卫生间 防水处理 地面坡度 geothermal heating toilet waterproof treatment slope of ground
  • 相关文献

参考文献1

二级参考文献3

  • 1GB50204-2002.混凝土结构工程施工质量验收规范[S].[S].,2002..
  • 2张文阁.怎样做好屋面、卫生间地面的试水工作.建筑工人,2001,(1):15-16.
  • 3GB50209-2002.建筑地面工程施工质量验收规范[S].[S].,..

共引文献4