CT引导下肺部肿瘤射频消融术胸膜反应的防治(附10例临床报告) 被引量:1

The prevention and treatment regard pleural reaction in the CT-guided lung tumor radiofrequency ablation(Report of 10 cases)
下载PDF
导出
摘要 目的探讨CT引导下肺部肿瘤射频消融术胸膜反应的原因及诊疗措施。方法对10例在射频消融术中发生胸膜反应的患者资料进行回顾性分析。结果胸膜反应的发生与患者心理因素、生理因素、温度因素和肿瘤位置相关。结论通过术前和术中的有效干预与治疗可以降低胸膜反应的发生。 [ Objective] To investigate the reasons and treatment measures of pleural response which is caused by CT-guided lung tumor radiofrequeney ablation. [Method] Retrospective analysis about 10 patient occurred pleural reaction during CT-guided lung tumor radiofrequency ablation treatment was made. [ Result] Pleural reactions were related to psychological factors, physiological factors, temperature factors and the location of the tumor. [ Conclusion] Effective intervention and treatment during preoperative and intraoperative stage can reduce the incidence of pleural reactions.
出处 《中国现代医学杂志》 CAS CSCD 北大核心 2011年第18期2158-2160,2163,共4页 China Journal of Modern Medicine
关键词 CT 射频消融:胸膜反应 CT radiofrequency ablation pleural reactions