期刊文献+

A Method for Determination of Hexokinase Activity by RP-HPLC

A Method for Determination of Hexokinase Activity by RP-HPLC
原文传递
导出
摘要 A method was established to determine the activity of hexokinase by reverse-phase high-performance liquid chromatography (RP-HPLC). The activity of hexokinase was determined by detecting the amount of ADP in the reaction that converts glucose into glucose-6-phosphate. The separation degree of ATP and ADP was as good as 3.46 (separation degree^l.5). In the range of 0.01-0.40 mmol/L, there was a good linear relationship between concentration of ADP and its peak areas (the correlation coefficient was 0.999). The relative standard deviation(RSD) of intraday was 1.43%-1.46%, that of interday was 2.12%-2.15%. At 30℃ (optimal temperature) and pH7.0 (optimal pH), the recovery rate of hexokinase was 95.3%-97.6%. The results showed that the method had good precision and high recovery rate, and the enzyme activity was determined through only one-step reaction. To some extent, this method can reduce the cost. A method was established to determine the activity of hexokinase by reverse-phase high-performance liquid chromatography (RP-HPLC). The activity of hexokinase was determined by detecting the amount of ADP in the reaction that converts glucose into glucose-6-phosphate. The separation degree of ATP and ADP was as good as 3.46 (separation degree^l.5). In the range of 0.01-0.40 mmol/L, there was a good linear relationship between concentration of ADP and its peak areas (the correlation coefficient was 0.999). The relative standard deviation(RSD) of intraday was 1.43%-1.46%, that of interday was 2.12%-2.15%. At 30℃ (optimal temperature) and pH7.0 (optimal pH), the recovery rate of hexokinase was 95.3%-97.6%. The results showed that the method had good precision and high recovery rate, and the enzyme activity was determined through only one-step reaction. To some extent, this method can reduce the cost.
出处 《Wuhan University Journal of Natural Sciences》 CAS 2011年第6期535-540,共6页 武汉大学学报(自然科学英文版)
基金 Supported by the Key Project of Science and Technology Department of Fujian Province (2008Y0052)
关键词 reverse-phase high-performance liquid chromatog-raphy(RP-HPLC) HEXOKINASE enzyme activity assay reverse-phase high-performance liquid chromatog-raphy(RP-HPLC) hexokinase enzyme activity assay
  • 相关文献

参考文献4

二级参考文献27

  • 1彭霞,胡晓燕.离子对反相色谱法同时测定钢铁及合金中锆和铪[J].冶金分析,2005,25(1):23-26. 被引量:6
  • 2雒丽娜,董慧茹,张建军,徐采霞,刘开录,赵京城.正相色谱和反相色谱法分离提纯东北红豆杉中紫杉醇和三尖杉宁碱[J].分析科学学报,2006,22(1):17-20. 被引量:5
  • 3高如瑜,祝凌燕.反相液相色谱分析三苯基磷[J].精细石油化工,1997,14(1):57-59. 被引量:1
  • 4香山科学会议.科学前言与未来(第六集)[M].北京:中国环境科学出版社,2002.80-89.
  • 5邹汉法 张玉奎 卢佩章.高效液相色谱法[M].北京:科学出版社,2001.152-157.
  • 6汪尔康.21世纪的分析化学[M].北京:科学出版社,2001.269-284.
  • 7唐有祺,王夔.化学与社会[M].北京:高等教育出版社,2000:89-91.
  • 8施耀,张清宇,吴祖成,等.21世纪的环保理念[M].北京:化学工业出版社,环境科学与工程出版中心,2002 :300-306.
  • 9Murakami K,Kanno H,Tancabelic J,et al.Gene expression and biological significance of hexokinase in erythroid cells[J].Acta Haematol,2002,108(4):204-209.
  • 10Kanno H.Hexokinase:gene structure and mutations[J].Baillieres Best Pract Res Clin Haematol,2000,13(1):83-88.

共引文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部