期刊文献+

Theory and experimental verification of valveless piezoelectric pump with rotatable unsymmetrical slopes 被引量:8

Theory and experimental verification of valveless piezoelectric pump with rotatable unsymmetrical slopes
原文传递
导出
摘要 A valveless piezoelectric pump with rotatable unsymmetrical slopes is developed in this research.It has the following features:The pump integrates driving and transporting,and it can mix different fluids while transporting them.In this paper,firstly,the design of the valveless piezoelectric pump with rotatable unsymmetrical slopes was proposed,and the single-direction flow principle was explained.Then,the fluid mechanics model of the valveless piezoelectric pump with rotatable unsymmetrical slopes was established.Meanwhile,the numerical simulation of the pump was performed.Finally,the experiments on relationship between the rotation angles of the slope and the flow rates were conducted.The experimental results showed that the maximum flow was 32.32 mL min 1.The maximum relative error between the theoretical results and the experimental ones was 14.59%.For the relationship between rotation angles and flow ratio of two inlets,the relative error between the experimental and theoretical maxima was 3.75%.Thus,the experiments proved the feasibility of the pump design and verified the theory. A valveless piezoelectric pump with rotatable unsymmetrical slopes is developed in this research. It has the following features: The pump integrates driving and transporting, and it can mix different fluids while transporting them. In this paper, firstly, the design of the valveless piezoelectric pump with rotatable unsymmetrical slopes was proposed, and the single-direction flow principle was explained. Then, the fluid mechanics model of the valveless piezoelectric pump with rotatable unsymmetrical slopes was established. Meanwhile, the numerical simulation of the pump was performed. Finally, the experiments on relationship between the rotation angles of the slope and the flow rates were conducted. The experimental results showed that the maximum flow was 32.32 mL min^-1. The maximum relative error between the theoretical results and the experimental ones was 14.59%. For the relationship between rotation angles and flow ratio of two inlets, the relative error between the experimental and theoretical maxima was 3.75%. Thus, the experiments proved the feasibility of the pump design and verified the theory.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第11期3070-3077,共8页 中国科学(技术科学英文版)
基金 supported by the National Natural Science Foundation of China (Grant Nos. 50775109 and 51075201) the Important Projects of National Science Foundation of China (Grant No. 50735002) Open Fund of State Key Lab of Digital Manufacturing Equipment and Technology (Grant No. DMETKF2009002)
关键词 无阀压电泵 旋转角度 不对称 实验 验证 流体力学模型 最大相对误差 研究开发 piezoelectric, pump, valveless, rotatable, unsymmetrical slope
  • 相关文献

参考文献18

二级参考文献72

共引文献126

同被引文献34

引证文献8

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部