摘要
代替传统的通过效率刻度测量131Ⅰ活度的方法,借助于MCNP5模拟和求解病态矩阵方程得出131Ⅰ在取样滤盒中的深度分布和总活度。该方法稳定性良好,无需制备标准样品和效率刻度,有利于快速准确地监测131Ⅰ的排放;可以给出深度分布,有助于了解131Ⅰ在取样盒中的物理进程。
Instead of the traditional methord for measuring 131Ⅰ activation by calibrating the detecting efficiency,MCNP5 caculation and ill-posed equation solution were used in a new methord for analysing 131Ⅰ activation and depth distribution in sample box.Because of no necessary to prepare for standard sample and calibrate the efficiency,it makes the survey of 131I more quickly and accurately and is able to take into account the physics processes of 131Ⅰ in the sample box.
出处
《核电子学与探测技术》
CAS
CSCD
北大核心
2011年第8期867-870,共4页
Nuclear Electronics & Detection Technology
关键词
131Ⅰ活度
深度分布
病态矩阵
吉洪诺夫正则化
activation of 131Ⅰ
depth distribution
ill-posed matrix
Tikhonov regularization