采用IED-2000能量色散X射线荧光仪测量化探样品,并对获得的仪器谱进行散射本底扣除和直接解调谱线重建,获得W的Lα特征X射线全能峰净峰面积,从而实现W含量的测量。对同一批化探样品进行室内波长色散X射线荧光分析和野外X射线荧光分析,其分析结果对比表明对能量色散X射线荧光仪进行谱线处理后,可以在野外现场对W元素实现半定量分析,为野外现场W元素测量提供了方法。
The background estimated by FFT and the direct demodulation method are applied to Energy Dispersive X-ray Fluorescence analysis(EDXRF).The method is used to calibrate the X-ray fluorescence analyzer which measures content of Tungsten,getting the coefficients.The X-ray fluorescence analyzer is used to analyze the content of Tungsten in the geochemical exploration samples.The result from the x-ray fluorescence analyzer is close to the result from the wavelength dispersive X-ray fluorescence analyzer.So used background estimated by FFT and the direct demodulation method,the x-ray fluorescence analyzer can be used to analyze the content of Tungsten in the geochemical exploration samples.
出处
《核电子学与探测技术》
CAS
CSCD
北大核心
2011年第8期887-890,共4页
Nuclear Electronics & Detection Technology
基金
863计划项目"海底原位X射线探针分析系统研制"(2006AA092219)
中国地质调查局地质调查工作项目"西天山航磁异常查证野外X荧光示范"资助
关键词
野外X射线荧光分析
化探样品
W含量
FFT本底扣除算法
直接解调方法
in-situ energy dispersive X-ray fluorescence analysis
the geochemical exploration samples
content of Tungsten
background estimated by FFT
direct demodulation method