期刊文献+

基于Geant4的盖革计数管能量补偿研究 被引量:6

The Energy Compensation Study of Geiger-Mueller Tube Based on Geant4
下载PDF
导出
摘要 重点研究了盖革计数管对于较宽能量范围的各能量γ射线的响应情况,从理论上简要说明了盖革计数管的能量响应特点,并针对国产的J4403型计数管使用蒙特卡罗软件Geant4分析了实际情况下能量补偿的各个影响因素,得到不同结构参数下计数管的能量响应情况,为计数管的能量补偿提供了依据。 The energy response of Geiger-Mueller(GM) tube to ga mma radiation in wide energy range is mainly researched,and characteristics of energy response are briefly explained in theory.Some factors that influence energy response are analysed in the model of J4403 tube by Geant4.The analysis obtains energy response of compensated tube with various compensation shields,which provides the foundation for energy compensation.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第8期912-915,共4页 Nuclear Electronics & Detection Technology
关键词 盖革计数管 能量补偿 GEANT4 Geiger-Mueller tube energy compensation Geant4
  • 相关文献

参考文献3

  • 1李继源,来永芳,邹本日,张皓.G-M计数管的可靠性[J].核电子学与探测技术,2001,21(2):89-93. 被引量:10
  • 2D. Barclay. Improved Response of Geiger Muller Detectors [ J ]. IEEE Transactions on Nuclear Science, 1986,33( 1 ) :613 -616.
  • 3Geant4 User' s Guide for Application Developers, Geant4 Collaboration, December 17,2010.