摘要 常规实验室血液标本的处理质量对于帮助实验室在识别、减少以及消除来自血液标本不恰当处理的分析前阶段中的误差非常重要。通过查阅临床和实验室标准化研究院(CLSI)等参考文献规范血液标准的处理程序,总结了对全血标本、血清、血浆样本恰当的处理程序,强调了标本处理的离心前(标本运输的时间和温度、试管方向、标本溶血、标本暴露于光下、自动化传输系统、实验室标本拒收标准等)、离心时(温控离心机、再离心)及离心后阶段(血清/血浆标本的储存、防腐剂等)相关的变量。 The quality of the handling procedures for blood specimen can help laboratories in reognizing, reducing, or removing the en'ors fi'om inappropriate handling procedures of blood specimen. This paper consuhs reference articles from CLSI to standardize the hmldling procedures of blood specimen. Having sumnmrized the handling procedures (ff specimen of whole blood, serum, plasma, emphasizing the relatively vari',d^les of specimen handling in pre-centrifugation (time and temperature of specimen transportation, tube orientation, hemolysis, exposure to light, automated delivery systems, criteria for specimen rejection etc). eentlifugation(temperature-eontrolled centrifuges, recentrifugation )mid post-centrifugation (storage, ponservatives etc.
作者 杨雪 王治国
出处 《中国医院》 2011年第11期61-64,共4页 Chinese Hospitals
关键词 常规实验室 血液标本 检验质量 质量管理 common laboratory, blood samples, quality inspection, quality management
  • 相关文献

参考文献5

  • 1Garcia-Bujalance S,Ladronde Guevara C,Gonzalez-GarciaJ,et al.Elevation of viral load byPCR and use of plasma preparationtubes for quantification of humanimmunodeficiency virus type 1[].JMicrobiol Methods.2007
  • 2Adcock DM,Kressin DC,Marlar RA.Minimum specimenvolume requirements for routinecoagulation testing[].American Journal of Clinical Pathology.1998
  • 3Pewarchuk W,VanderBoom J,Blajchman MA.Pseudopolycythemia,pseudothrombocytopenia,andpseudoleukopenia due to overfilling ofblood collection vacuum tubes[].Archives of Pathology and Laboratory Medicine.1992
  • 4Clinical Laboratory StandardsInstitute.Procedures for the handlingand processing of blood specimens forcommon laboratory tests;approvedguideline—fourth edition[].CLSIdocument H-A.2010
  • 5Haverstick D,Brill L,Scott MG,etal.Preanlytical variables in measurementof free(ionized)calcium in lithiumheparin-containing blood collectiontubes[].Clinica Chimica Acta.2009

同被引文献28

  • 1黄海国,辛锡龙.血清标本放置时间、离心速度及吸样对血脂测定的影响[J].现代中西医结合杂志,2004,13(18):2466-2467. 被引量:2
  • 2李金明.感染性疾病血清学检验中应重视对弱反应性标本的确认[J].中华检验医学杂志,2006,29(7):577-580. 被引量:126
  • 3徐春茂.高速离心法消除脂浊对生化结果的影响[J].现代检验医学杂志,2007,22(5):35-35. 被引量:5
  • 4Ajit Sharma, Karen Anderson, and Jon W Baker. Flocculation ofSerum Lipoproteins withCyclodextrins: application to assay of hy-perlipidemic serum[J]. Clin Chem,1990,36(3) :529-532.
  • 5段满乐.生物化学检验[M].3版.北京:人民卫生出版社,2011:145.
  • 6CLSI. MM06-Quantitative Molecular Methods for Infectious Diseases.A Approved Guideline-Second Edition CLSI document[J].Wayne PA:CLSI,2010.
  • 7王治国.临床检验方法确认与性能验证[M]北京:人民卫生出版社,20091.
  • 8王治国.临床检验质量控制技术[M]北京:人民卫生出版社,20081.
  • 9李金明.实时荧光PCR技术[M]北京:人民军医出版社,20101.
  • 10Stevenson J,Hymas W,Hillyard D. Effect of sequence polymor phisms on performance of two real-time PCR assays for detection of herpes simplex virus[J].Journal of Clinical Microbiology,2005,(05):2391-2398.doi:10.1128/JCM.43.5.2391-2398.2005.

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部