大型合流制污水干管优化运行研究 被引量:6

下载PDF
导出
摘要 大型合流制污水干管已成为众多城市合流污水收集与集中输送排放的重要组成部分。建立上海市合流污水一期工程干管水力模型,对典型旱天和雨天工况进行模拟分析,为优化干管运行提供了技术支撑。提出了旱天优化运行模式,可实现防淤积、削减溢流、均化水量、节能降耗等多方面目标。指明了合流制污水干管初期雨水不放江的临界降雨强度,验证了当干管系统遭遇不均匀强降雨时,提高相应支线泵站截流量以减少污水放江的可行性,为指导干管优化运行的生产实践提供科学依据。
出处 《给水排水》 CSCD 北大核心 2011年第11期97-101,共5页 Water & Wastewater Engineering
  • 相关文献

参考文献9

  • 1US EPA. Combined Sewer Overflow (CSO) Control Policy. Federal Register, 1994,59(75) : 18688-18698.
  • 2US EPA . Combined Sewer Overflows Guidance for Monitoring and Modeling. EPA 832-B-99-002 January 1999.
  • 3Weyand M. Real - time control in combined sewer systems in Germany-some case studies, urban water(20024):347-354.
  • 4Jorgensen M, Schilling S, Harremoes P. General Assessment of potential CSO reduction by means of Real Time Control. Wat. Sci. Tech. 1995,32(1) :249-257.
  • 5Rauch W, Harremoes P. Correlation of combined sewer overflow reduction due to real - time control and resulting e~fect on the oxygen concentration in the river. Wat. Sci. Tech,1998, 37(12):69-76.
  • 6Pleau M, Colas H, Lavallee P, et al. Global optimal real - time control of the Quebec urban drainge system. Environmental Modelling ~Software, 2005, (20) :401-413.
  • 7Adderley V, Mandilag A. Portland's CSO program Modeling: reflecting the city's Priorities for CSO and stormwater pollutants using Real Time Controls. ASCE Urban Drainage 2002.
  • 8王喜冬.香港岛污水管网系统总体规划概述[J].给水排水,2004,30(12):103-105. 被引量:10
  • 9上海市政工程设计院.上海市合流污水治理一期工程初步设计,1986.