摘要 目的:实现基于GPUs的心脏断层图像的精确分割和三维可视化,完成心脏辅助诊断系统的设计。方法:结合临床专家诊断经验、心脏CT图像先验特征和图像分割算法模型,采用GPUs并行数据处理技术实现心脏结构的分割和三维可视化。结果:完成了CT心脏序列图像的精确、快速、鲁棒分割和三维可视化,初步实现了基于GPUs的可视化技术的心脏辅助诊断系统。结论:研究充分利用计算机图形处理单元GPU强大的并行计算能力,解决了医学图像处理和分割中的问题,提高了程序的运行效率,改善了用户体验。 Objective To develop a real-time CAD system of cardiac medical image.Methods In combination with diagnosis experience of clinical experts and cardiac CT images and image segmentation model,GPUs parallel computing capacity was employed to realize cardiac structure segmentation and 3D visualization.Results Cardiac CT images could be segmented accurately,precisely and robustly in 3D visualization.Cardiac diagnosis-assisted system was realized based on GPUs visualization.Conclusion GPUs parallel computing capacity of CAD system is utilized to process and segment medical images,which raise the running efficiency.
出处 《医疗卫生装备》 CAS 2011年第10期16-18,共3页 Chinese Medical Equipment Journal
基金 华南理工大学中央高校基本科研业务费专项资金资助(2009ZM0235)
关键词 专家系统 心脏 双源CT CUDA GPUS expert diagnosis system cardiac DSCT CUDA GPUs
  • 相关文献

参考文献8

  • 1Maryellen L G,Nico K,Samuel G A,et a!. Computer-aided diag- nosis in medical imaging[J]. IEEE Transaction on Medical Imaging, 2001,20:1 275-1 279.
  • 2Bram V G,Bart M H. Computer-aided diagnosis in chest radiography: a survey [J]. IEEE Transaction on Medical Imaging, 2001,20: 1 228-1 241.
  • 3张立波,杨本强,周丽娟,邹明宇,刘文源.野战卫勤医学影像学远程交互式诊断系统的研制[J].医疗卫生装备,2010,31(9):37-39. 被引量:2
  • 4Wei Hua. Epidemiological investigation of sudden cardiac death in china[J]. J Am Coil Cardiol,2009,54:1 110.
  • 5张龙江,卢光明.双源CT及其临床应用[J].中华放射学杂志,2008,42(2):206-208. 被引量:65
  • 6Vineet Vibhav,Narayanan P J. CudaCuts: Fast Graph Cuts on the GPU [C]//IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops, Hyderabad, India, 2008 : 1-8.
  • 7Kolmogorov V ,Zabih R. What energy functions can beminimized via graph cuts[J]. IEEE Trans Pattern Anal Mach Intell,2004,26 (2): 147-159.
  • 8储璟骏,杨新,高艳.使用GPU编程的光线投射体绘制算法[J].计算机辅助设计与图形学学报,2007,19(2):257-262. 被引量:33

二级参考文献45

  • 1张建勋,刘全利,陈庄.基于可编程GPU的快速体绘制技术[J].重庆大学学报(自然科学版),2005,28(7):67-70. 被引量:9
  • 2宋涛,欧宗瑛,王瑜,李冠华,刘斌.八叉树编码体数据的快速体绘制算法[J].计算机辅助设计与图形学学报,2005,17(9):1990-1996. 被引量:24
  • 3Flohr TG, Schoepf UJ, Ohnesorge BM. Chasing the heart: new developments for cardiac CT. J Thorac Imaging,2007,22:4-16.
  • 4Flohr TG, MeCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006,16:256-268.
  • 5Ohnesorge BM, Flohr TG, Becker CR, et al. Multi-slice and dual-source CT in cardiac imaging: principles, protocols, indications, and outlook. 2nd ed. Berlin : Springer-Verlag, 2007, 327-358.
  • 6Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol, 2006,16:2739-2747.
  • 7McCollough CH,Primak AN ,Saba O,et al. Dose performance of a 64-ehannel dual-source CT scanner. Radiology, 2007, 243 : 775-784.
  • 8Achenbach S, Ropers D, Kuettner A, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience. Eur J Radiol, 2006,57:331-335.
  • 9Schoepf UJ, Zwemer PL, Savino G, et al. Coronary CT angiography. Radiology,2007,244:48-63.
  • 10Lescohka S, Scheffel H, Desbiolles L, et al. Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol, 2007,42:543-549.

共引文献97

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部