摘要
简要介绍了医院消毒供应中心气体控制的目标与要求,提出了气流控制的区域及其技术指标的建议值,通过对定风量控制系统、双稳态控制系统和变风量控制系统3种气流控制方案的技术经济比较,指出了空气过滤技术结合变风量技术是实现医院消毒供应中心"空气流向从洁到污"的最佳组合方案。
The goals and requirements of air-flow control in CSSD are introduced.The control region and suggested technology values of the air-flow control programs are put forward.Among three types of air-flow control programs,the combination of air filter and VAV are the best choice for technical solutions of "air-flow from clean to dirty" in CSSD.
出处
《医疗卫生装备》
CAS
2011年第10期114-115,122,共3页
Chinese Medical Equipment Journal