期刊文献+

Management with the insufficient proximal landing zone for endovascular repair in aortic dissection 被引量:6

Management with the insufficient proximal landing zone for endovascular repair in aortic dissection
原文传递
导出
摘要 Background Sufficient length of the proximal landing zone (PLZ) is the key for a successful thoracic endovascular aortic repair (TEVAR) of an aortic lesion. The aim of this research was to investigate the safety, feasibility, efficacy, and problems of endovascular repair for aortic dissection with insufficient PLZ.Methods The clinical data between August 2005 and February 2010 from patients with insufficient PLZ for endovascular repair of aortic dissection were retrospectively reviewed. According to the classification proposed by Ishimaru, aortic zone 0 was involved in 3 cases, zone 1 in 10 cases, and zone 2 in 11 cases. A hybrid surgical procedure of supraortic debranching and revascularization, directly coverage the orifice of left subclavian artery, or a left common carotid artery chimney graft technique were performed to obtain an adequate proximal aortic landing zone.Results There was no significant difference in risk factors and diameter of the PLZ between Zone 0, Zone 1, and Zone 2. But the length of the PLZ was significantly different in the three groups (P 〈0.01). There was no significant difference in technical and clinical success rate between the groups.Conclusions The procedure for extending an insufficient PLZ for endovascular repair for aortic arch pathology is feasible and relatively safe. The applicability of TEVAR in such aortic disorders may be expanded. Background Sufficient length of the proximal landing zone (PLZ) is the key for a successful thoracic endovascular aortic repair (TEVAR) of an aortic lesion. The aim of this research was to investigate the safety, feasibility, efficacy, and problems of endovascular repair for aortic dissection with insufficient PLZ.Methods The clinical data between August 2005 and February 2010 from patients with insufficient PLZ for endovascular repair of aortic dissection were retrospectively reviewed. According to the classification proposed by Ishimaru, aortic zone 0 was involved in 3 cases, zone 1 in 10 cases, and zone 2 in 11 cases. A hybrid surgical procedure of supraortic debranching and revascularization, directly coverage the orifice of left subclavian artery, or a left common carotid artery chimney graft technique were performed to obtain an adequate proximal aortic landing zone.Results There was no significant difference in risk factors and diameter of the PLZ between Zone 0, Zone 1, and Zone 2. But the length of the PLZ was significantly different in the three groups (P 〈0.01). There was no significant difference in technical and clinical success rate between the groups.Conclusions The procedure for extending an insufficient PLZ for endovascular repair for aortic arch pathology is feasible and relatively safe. The applicability of TEVAR in such aortic disorders may be expanded.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第19期3003-3007,共5页 中华医学杂志(英文版)
关键词 endovascular procedures aortic dissection proximal landing zone aorta thoracic endovascular procedures aortic dissection proximal landing zone aorta, thoracic
  • 相关文献

参考文献2

二级参考文献41

  • 1Mobs BE,Balm R,White GH,Verhagen HLJM.Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture.J Vasc Surg 2007; 45:655-661.
  • 2Ohrlander T,Sonesson B,Ivancev K,Resch T,Dias N,Malina M.The chimney graft:a technique for preserving or rescuing aortic branch vessels in stent-graft sealing zones.J Endovasc Ther 2008; 15:427-432.
  • 3Steinbaner MGM,Stehr A,Pfister K,Herold T,Zorger N,Topel I,et al.Endovascular repair of proximal endograft collapse after treatment for thoracic aortic disease.J Vasc Surg 2006; 43:609-612.
  • 4Tsetis D.Endovascular treatment of complications of femoral arterial access.Cardiovasc Intervent Radiol 2010; In press.
  • 5Koreny M,Riedmuller E,Nikfardjam M,Siostrzonek P,Mullner M.Arterial puncture closing devices compared with standard manual compression after cardiac catheterization:systematic review and meta-analysis.JAMA 2004; 291:350-357.
  • 6Clouse WD,Hallett JW Jr,Schaff HV,Spittell PC,Rowland CM,Ilstrup DM,et al.Acute aortic dissection:population-based incidence compared with degenerative aortic aneurysm rupture.Mayo Clin Proc 2004; 79:176-180.
  • 7Olsson C,Thelin S,Stahle E,Ekbom A,Granath F.Thoracic aortic aneurysm and dissection:increasing prevalence and improved outcomes reported in a nationwide population-based study of more than 14000 cases from 1987 to 2002.Circulation 2006; 114:2611-2618.
  • 8Dake MD,Kato N,Mitchell RS,Semba CP,Razavi MK,Shimono T,et al.Endovascular stent-graft placement for the treatment of acute aortic dissection.N Engl J Med 1999; 340:1546-1552.
  • 9Eggebrecht H,Nienaber CA,Neuhauser M,Baumgart D,Kische S,Schmermund A,et al.Endovascular stent-graft placement in aortic dissection:a meta-analysis.Eur Heart J 2006; 27:489-498.
  • 10Buth J,Harris PL,Hobo R,van Eps R,Cuypers P,Duijm L,et al.Neurologic complications associated with endovascular repair of thoracic aortic pathology:Incidence and risk factors.a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR)registry.J Vasc Surg 2007; 46:1103-1110.

共引文献20

同被引文献16

引证文献6

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部