摘要
目的:比较福尼亚智能型胰岛素泵与普通胰岛素泵治疗糖尿病的效果及安全性。方法:选取我院80例2型糖尿病患者,将其分为两组,普通胰岛素泵组(A组)38例,福尼亚智能胰岛素泵组(B组)42例,比较两种胰岛素泵在控制血糖水平、低血糖发生率、血糖达标时间等方面的差别。结果:两组在血糖控制水平及血糖达标时间方面比较,差异无统计学意义(P>0.05),低血糖发生率B组低于A组(P<0.01)。结论:福尼亚智能胰岛素泵低血糖发生少,安全性更高。
Objective: To compare the therapeutic effects and safety of Fomia intelligence insulin pump and normal insulin pump in the treatment of diabetes mellitus. Methods: 80 patients with type 2 diabetes mellitus were randomly divided into two groups, normal insulin pump group (group A, n=38) and Fomia intelligence insulin pump group (group B, n= 42). The level of blood glucose, the rate of hypoglycemic episodes and the time of blood glucose for achieving the target were compared between two groups. Results: No significant differences were found in the blood glucose levels and the time of blood glucose for achieving the target between two groups (P〉0.05), The hypoglycemic episode of group B was lower than that of group A (P〈0.01). Conclusion: Fomia intelligence insulin pump can control safety and stability of blood glucose and decrease hypoglycemic episodes.
出处
《中国医药导报》
CAS
2011年第31期188-189,共2页
China Medical Herald
关键词
糖尿病
胰岛素输注系统
低血糖
Diabetes mellitus
Insulin pump system
Hypoglycemic