摘要 针对现场实际,提出了油浸式变压器的状态评估模型及评估方法。模型结合变电运行、检修及在线监测系统数据,将变压器运行状态按层次结构进行评估。评估方法综合采用层次分析(AHP)、模糊层次分析(FAHP)方法进行了各层、各隶属级指标的静态权重及静态相对权重确定,根据各指标劣化程度提出了指标的关注度及相对关注度,并与静态相对权重结合提出劣化变权方法,在此基础上采用改进证据理论方法实现融合评估。实际算例分析表明,所建模型及评估方法能支持各相关指标,在把握变压器各部件状态的同时,可有效突出各指标的劣化程度,能有效指导现场变压器状态评估。 Combining the data collected from tansformer operation, maintenance and on-line monitoring system, an oil-immersed trans- former assessment hierarchy model and its assessment approach are presented according to the actual production. AHP method and FAHP method are integrated to identify the static relative weights of indicators. Degree of attention and relative degree of attention are defined concerning the degradation of the indicators. Then combining the static relative weights and relative degree of attention, the vari- able weights of degradation is defined and used as the correction factor of evidence. An improved evidence reasoning is performed on the basis of revised evidences to deduce the state of components of a transformer, according to the value sequence of the variable weights. Analysis of a practical example shows that the model and the approach are able to support the indicators, and can give the health status of the various components of transformers while effectively highlighting the degradation. The assessment model and approach can effectively guide the condition assessment of transformers in practice.
出处 《控制工程》 CSCD 北大核心 2011年第6期881-885,共5页 Control Engineering of China
基金 国家自然科学基金资助项目(50677062) 新世纪优秀人才支持计划资助(NCET-07-0745) 浙江省自然科学基金资助项目(R107062) 国家863计划(2008AA05Z210) 教育部博士点基金资助项目(20090101110058)
关键词 变压器 AHP FAHP 可能度排序 劣化变权 改进证据理论 状态评估 transformer AHP FAI-IP possibility degree ranking variable weights of degradation improved DS theory condition assessment
  • 相关文献

参考文献16

  • 1Tang W H, Spurgeon K, Wu Q H. An evidential reasoning approach to transformer condition assessments [ J ]. IEEE Transactions on Power Delivery, 2004, 19 (4) : 1696-1703.
  • 2Yadavl R, Kumar S, Venkatasami A, et al. Condition based maintenance of power transformer:a case study [ C]. Beijing, China: International Conference on Condition Monitoring and Diagnosis, 2008.
  • 3Scillia P, Kafi S A, Melot C, et al. Oleic acid-induced lung injury: thin-section CT evaluation in dogs[J]. Radiology, 2001, 219(3): 724-731.
  • 4朱永利,申涛,李强.基于支持向量机和DGA的变压器状态评估方法[J].电力系统及其自动化学报,2008,20(6):111-115. 被引量:23
  • 5廖瑞金,王谦,骆思佳,廖玉祥,孙才新.基于模糊综合评判的电力变压器运行状态评估模型[J].电力系统自动化,2008,32(3):70-75. 被引量:218
  • 6朱承治,郭创新,孙旻,辛建波.基于改进证据推理的变压器状态评估研究[J].高电压技术,2008,34(11):2332-2337. 被引量:35
  • 7何雷,李丽平.基于云模型的电力变压器状态综合评判[J].华北电力大学学报(自然科学版),2009,36(3):98-103. 被引量:13
  • 8Soreide E, Harboe S, Sondenaa K, et al. Severe ARDS may cause right heart failure with extreme hepatomegaly but without hepatic failure[J]. Acta Anaesthesiol Scand, 2002, 46(7): 906-907.
  • 9Taylor D E. Reviewing the motor of multiple organ dysfunction syndrome. Gut dysfunction in ARDS and multiple organ failure[J]. Respir Care Clin N Am, 1998, 4(4): 611-631.
  • 10Carroll P. Monitoring the gut to prevent MODS[J]. RN, 1999, 62(10): 34-37.