摘要
针对某220kV变电站选址位置周边环境条件恶劣的情况,对区域内的土壤、大气和水源进行检测,通过地埋和悬挂金属片进行金属腐蚀试验分析,认为此选址环境对电力设备和金属材料腐蚀影响非常严重,不宜建变电站,并提出变电站选址的建议。
This paper solves the problem of 220 kV substation locating where the ambient environment is rather tough.Through environment measuring on the surrounding soil,atmosphere and water source,it was verified that substation apparatus would be seriously eroded if built at the location.Thorough corroding proof tests on undergrounded and suspended sheet metals were conducted.The conclusion is that such a site is not suitable for substation construction,and further site selection is advised.