摘要 目的:评价3.0T高时间分辨率对比增强磁共振血管成像(TR 3DCE-MRA)在颅内血管成像的技术可行性和临床应用价值。方法:经医院伦理委员会批准,回顾性搜集21例患者,采用3.0T磁共振,首先行常规序列T1WI、T2WI和TOF MRA扫描,然后在确定病变处用TR 3DCE-MRA即快速小角度激发梯度回波序列(3DFLASH)。所有病例在检查后1~3d行高分辨率增强MRA(HR CE-MRA),测量动脉的信噪比和对比噪声比,由2位影像专家对TR CE-MRA和HR CE-MRA图像质量进行评价,分别对图像伪影、静脉污染、脑动脉显示效果进行评分。评分结果采用SPSS 13.0进行统计学分析,差异具有统计学意义(P<0.05)。结果:21例患者中动脉瘤3例,动静脉畸形7例,烟雾病2例,动脉狭窄9例。图像SNR和CNR测量均值分别为237±89和213±94,Wilcoxon test检验结果Z=-3.160,P=0.002<0.05,静脉污染组Z=-4.298,P=0.001<0.01,血管显示组Z=-4.491,P=0.001<0.01,差异有明显统计学意义。结论:TRCE-MRA比HR CE-MRA具有严重伪影少,没有静脉污染,良好的血管对比,能够同时评价动脉血管和静脉血管,将是颅内血管疾病的首选。 Objective:To evaluate the feasibility and clinical value of time resolved contrast enhanced three-dimension- al magnetic resonance (MR) angiography (TR 3D CE MRA) with 3.0T MR scanner of intracranial vasculature. Methods: Approved by the ethic committee of the hospital,21 patients underwent routine TlWI,T2WI and TOF MRA with a 3.0T MR scanner were retrospectively studied. After the lesion was revealed, all patients underwent TR 3D CE MRA with 3D FLASH sequence, then, single phase high spatial resolution contrast-enhanced three-dimensional magnetic resonance angi ography (HR CE 3D MRA) 1-3 days after was performed. The arterial signal-to-noise ratio (SNR) and contrast to noise ratio (CNR) were measured and the image quality were evaluated,as well as the image artifact,venous contamination and the contrast effect of cerebral arteries displayed on TR 3D CE MRA were compared to that of HR CE-MRA and scored by two radiologists. The results were analyzed with Wilconxon test using SPSSl3.0 software. Results:Of the 21 patients, there were aneurysm (n=3),arteriovenous malformation (n--7),moyamoya disease (n 2) and arterial stenosis (n=9). The mean value of SNR and CNR was 237q-89 and 213~94,respectively. The result of Wilcoxon test for the Group of artifact wereZ 3.160,P=0.002〈0.05;for Group of venous contamination were Z 4.298,P 0.001〈0.01,and for the contrast effect of cerebral arteries were Z=- 4. 491 ,P 0. 001 d0.01, with significant statistical differences. Conclusion: TR 3D CF MRA showed lesser severe artifacts,lesser venous contamination, better contrast enhancement of cerebral vascu lature,and ewduation of arterial and venous disease simultaneously was allowed,which could be used as the first choice for the diagnosis of intracranial vascular disease.
出处 《放射学实践》 北大核心 2011年第10期1089-1092,共4页 Radiologic Practice
关键词 磁共振血管造影术 脑血管障碍 图像增强 Magnetic resonance angiography Cerebro wlscular disorders Image enhancement
  • 相关文献

参考文献10

  • 1孔祥闯,孔祥泉,刘定西,王振平,徐海波,余建明.3.0T三维高时间分辨率对比增强MRA在四肢血管瘤的临床应用价值探讨[J].临床放射学杂志,2010,29(4):527-529. 被引量:3
  • 2Ruhl KM, Katoh M, Langer S, et al. Time resolved 3D MR angi- ography of the foot at 3T in patients with peripheral arterial dis ease[J]. AJR,2008,190(6) : 360- 364.
  • 3Krishnam MS, Tomasian A, Lohan DG, et al. Low-dose, time re solved, contrast enhanced 3D MR angiography in cardiac and vas-cular diseases correlation to high spatial resolution 3D contrast enhanced MRA[J]. Clinical Radiology, 2008,63 (7) : 744.
  • 4Cashen TA, Carr JC, Shin W, et al. Intracranial time resolved con trast-enhanced MR angiography at 3T[J]. Am J Neuroradiol, 2006,27(4) :822 -829.
  • 5Lim RP,Shapiro M,Wang EY,et al. 3D time resolved MR angiog raphy (MRA) of the carotid arteries with time resolved imagingwith stochastic trajectories: comparison with 3D contrast en- hanced bolus chase MRA and 3D time of flight MRA[J]. AJNR, 2008,29(9) :1847 -1854.
  • 6Korperich H, Gieseke J, Esdorn H, et al. Ultrafast time resolved contrast enhanced 3D pulmonary venous cardiovascular magnetic resonance angiography using SENSE combined with CENTRA- keyhole[J]. J Cardiovasc Magn Reson,2007,9(1):77- 87.
  • 7Hook O,Johanson C. Intracranial arteriovenous aneurysms: a fol low-up studywith particular attension to their growth[J]. Arch Ncurol Psy chiatry,1958,80(1) :39.
  • 8Zou Z,Ma L,Cheng L,et al. Time resolved contrast enhanced MR angiography of intracranial lesions[J]. J Magnetic Resonance Ima ging,2008 ,27 ( 4 ) :692.
  • 9Petkova M,Gauvrit JY, Trystram D, et al. Three-dimensional dy- namic time resolved contrast enhanced MRA using parallel ima-ging and a variable rate k space sampling strategy in intracranial arteriovenous malformations[J]. J Magnetic Resonance Imaging, 2009,29(1):7.
  • 10邬晴媛,林江.时间分辨磁共振动态增强血管成像技术和临床应用[J].临床放射学杂志,2010,29(5):701-703. 被引量:5

二级参考文献27

  • 1胡孝君,周海伟,邵海军,李春生.外周软组织血管瘤MRI表现与病理对照分析(附32例报告)[J].影像诊断与介入放射学,2007,16(1):31-33. 被引量:13
  • 2杨春山,张松,刘士远,肖湘生,周康荣,王金林,李惠民,肖珊,龚万庆.三维高时间分辨率动态增强MR血管成像在临床的初步应用[J].中华放射学杂志,2007,41(3):304-307. 被引量:8
  • 3崔晓琳,程敬亮,任翠萍,张炎,刘依凝,石士奎.软组织海绵状血管瘤的MRI诊断[J].实用放射学杂志,2007,23(3):371-373. 被引量:13
  • 4Ruhl KM,Katoh M,Langer S,et al. Time-Resolved 3D MR Angiography of the Foot at 3 T in Patients with Peripheral Arterial Disease. A JR ,2008,190:360.
  • 5Stepansky F, Hecht EM, Rivera R, et al. Dynamic MR Angiography of Upper Extremity Vascular Disease : Pictorial Review. RadioGraphics, 2008,28 : 28.
  • 6Zhang H, Maki JH, Prince MR. 3 D Contrast-Enhanced MR Angiography. Journal of Magnetic Resonance Imaging,2007,26 : 13.
  • 7Hedley AJ,Molan MP,Hare DL,et al. Nephrogenic systemic fibrosis associated with gadolinium-containing contrasl media administration in patients with reduced glomerular filtration rate. Nephrology,2007, 12:111.
  • 8Sadowski EA, Bennett LK, Chan MR,et al. Nephrogenic systemic fibrosis:risk factors and incidence estimation. Radiology, 2007,243 : 148.
  • 9Krishnam MS, Tomasian A, Lohan DG, et al. Low-dose, time-resolved,contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA. Clinical Radiology, 2008,63:744.
  • 10Hook O,Johanson C. Intracranial arteriovenous aneurysms. A follow- up study with particular attension to their growth. Arch Neurol Psychiatry, 1958,80 : 39.

共引文献5

同被引文献26

  • 1LI Ming-hua,GAO Bu-lang,FANG Chun,GU Bin-xian,CHENG Ying-sheng,WANG Wu,Giuseppe Scotti.Angiographic follow-up of cerebral aneurysms treated with Guglielmi detachable coils(GDCs): An analysis of 162 cases of 173 aneurysms[J].介入放射学杂志,2005,14(5):472-479. 被引量:6
  • 2全海英,毕伟,郑晓林,陈瞾,王志炜.三维增强MR脑血管成像技术探讨[J].放射学实践,2007,22(5):459-462. 被引量:2
  • 3杨正汉,冯逢,王霄英,等.磁共振技术应用指南[M].北京:人民卫生出版社,2005:320-322.
  • 4Schellinger P D,Jansen O,Fiebach J B,et al.Feasibility and practi-cality of M r imaging of stroke in the management of hyperacutecerebral ischemia[J].aJnr am J neuroradiol,2000:21:1 184-1 189.
  • 5Alfke K,Jensen U,Pool C,et al.Contrast-enhanced Magneticresonance angiography in stroke diagnostics[J].Clin neuroradiol,2011,21:5-10.
  • 6Cashen T A,Carr J C,Shin W,et al.Intracranial time-resolved con-trast-enhanced MR angiography at 3T[J].AJNR,2006,27(5):821-823.
  • 7Norris J W,Morriello F,Rowed D W,et al.Vascular imaging beforecaroti dendarterectomy[J].Stroke,2003,34(7):15-16.
  • 8Heiserman Je,Drayer B P,Keller P J,et al.Intracranial vascularstenosis and occlusion:evaluation with three-dimensional time-of-flight MR angiography[J].Radiology,1992,18(5):667-673.
  • 9Phan t,Huston J iii,Bernstein Ma,et al.Contrast-enhanced mag-netic resonance angiography of the cervical vessels:experience with422 patients[J].Stroke,2001,32:2 282-2 286.
  • 10Mitsuzaki K,Yamashita Y,Sakaguchi T,et al.Abdomen,pelvis,andextremities:diagnostic accuracy of dynamic contrast enhanced turboMR angiography compared with conventional angiography initialexperience[J].Radiology,2000,21(6):909-910.

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部