期刊文献+

Zeus麻醉机自动全禁闭目标控制麻醉的临床观察 被引量:1

下载PDF
导出
摘要 目的:研究Zeus麻醉系统自动全紧闭目标控制麻醉效果的可行性及安全性。方法:90例行腹腔镜胆囊切除术患者,随机分为两组,Ⅰ组为自动全紧闭目标控制麻醉组(Auto control),Ⅱ组为全紧闭控制麻醉组(Fresh gas control)各45例,记录在麻醉诱导前(T0),诱导后(T1),气管插管时(T2),气管插管后(T3),人工气腹建立后(T4)胆囊切除后(T5)拔除气管导管时(T6)的SDP、DBP、HR、PETCO2、BIS值及两组七氟烷的用量。结果:与T0时点比较,T1时点SDP、DBP、HR、BIS下降(P<0.05),T2时点SDP、DBP、HR、BIS下降(P<0.05),T3、T4、T5时点SDP、DBP、HR、BIS差异无统计学意义(P>0.05),T6时点SDP、DBP、HR差异无统计学意义,BIS值Ⅰ、Ⅱ组间比较差异无统计学意义(P>0.05)。结论:Zeus麻醉系统自动全紧闭目标控制麻醉效果可靠,可以达到节约麻醉药物,减少手术室内的污染。
作者 贾洪峰 刘瑶
机构地区 陕西汉中
出处 《航空航天医学杂志》 2011年第10期1205-1206,共2页 Journal of Aerospace medicine
  • 相关文献

参考文献3

二级参考文献15

  • 1[2]Swann,Spens H,Edwarxards SA,et al.Anaesthesia for gyraecological laparoscopy-a comparison between the laryngealmask airway andtracheal intubation.Anesthesia,1993,48(5):431
  • 2[3]Asai T,Morris S.Tne 1aryngeal mask airway:its features,effects and role.Can JAnaesth,1994,41(10):930
  • 3[4]Brimacombe J.Laparoscopy and laryngeal mask airway.Br J Anesth,1994,73(1):121
  • 4[6]Bapat PP, Verghese C. Laryngeal mask airway and the incidece of reguratation during gynecological laparoscopies. Anesth Analg, 1997,8(1):135
  • 5[7]Ho BYM, Skinner HJ, Mahajan RP. Gastro- oesophageal reflux during day case gynaecological laparoscopy under positive pressure ventilation:laryngeal mask vs tracheal intubation. Anaesthesia, 1998,53:910
  • 6[8]Bhath SB, Kendall AP, Lin ES, et al. Resistance and additional inpiretory work imposed by the laryngeal mask airway: A comparison with tracheal tubes. Anesthesia, 1992,47(2) :343
  • 7LUGINBUHL M,WUTHRICH S,PETEBSEN-FELIX S,et al.Diffferent benefit of bispectal index (BIS) in desflurane and propofol anesthesia[J].Aeta Anesthesiol Stand,2003,47:165-173.
  • 8JEAN W,DAJUN S,HANNAH BL,et al.Titration of ieoflurane using BIS index improves early reeevery of elderly palients undergoing orthopediesurgeries[J].Can J Anaesth,2002.49:13-18.
  • 9RECART A,GAEANOVA L WHITE PF,et al.The effect of cerebral monitoring on recovery after general anesthesia:a comparison of the auditory evoked potential and bispeetral index devices with standard clinical practice们.Anesth Analg,2003,97:1667-1674.
  • 10MUNTE S,MUNTE T F.GROTKAMP J,et al.Implicit memory varies as a function of hypnotic eleetrceneepha; ogram stage in surgical patients[J].Anesth Analg'2003,(1):132-138.