摘要 利用螯合作用,将银纳米粒子担载于碳纳米管表面,并用透射电镜、EDX、X射线衍射和电化学测试对该纳米杂化材料进行了表征.研究显示,碳纳米管表面的银纳米粒子颗粒小、粒径分布窄;该纳米杂化材料对过氧化氢有较强的催化作用,当过氧化氢浓度在50μmol/L~5mmol/L范围内,浓度与还原峰电流呈线性关系,显示出该纳米杂化材料在过氧化氢检测方面具有潜在的应用前景. Silver nanoparticles were loaded on the surface of carbon nanotubes via chelating method.The obtained nanohybrid structures were characterized by TEM,EDX,XRD and electrochemical technique.The results show narrow particle distribution of Ag nanoparticles was in the range of 1 to 5 nm.The nanohybrid has strong electrocatalytic effect on H2O2.When H2O2 ranges from 50 μmol·L-1 to 5 mmol·L-1,there is a good linearity relationship between H2O2 concentration and reductive peak current,which suggests the nanohybrid has the potential application in the determination of H2O2.
出处 《武汉工程大学学报》 CAS 2011年第10期61-64,共4页 Journal of Wuhan Institute of Technology
基金 国家自然科学基金项目(50903034 50873040) 华中科技大学材料成形与模具技术国家重点实验室开放基金课题(09-06) 武汉工程大学科学研究基金项目(11095032)资助
关键词 碳纳米管 纳米银 过氧化氢 生物传感器 carbon nanotubes silver nanoparticles hydrogen peroxide biosensor
  • 相关文献

参考文献2

二级参考文献11

  • 1Anthony G E,Lei C H,Baughman R H.Direct electron transfer of glucose oxidase on carbon nanotubes[J].Nanotechnology,2002,13:559-564.
  • 2Yin F,Shin H K,Kwon Y S.A hydrogen peroxide biosensor based on Langmuir-Blodgett technique:Direct electron transfer of hemoglobin in octadecylamine layer[J].Talanta,2005,67:221-226.
  • 3Tang H,Chen J H,Yao S Z,et al.Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode[J].Analytical Biochemistry,2004,331:89-97.
  • 4Lin Y H,Lu F,Tu Y,et al.Glucose biosensors based on carbon nNanotube nanoelectrode ensembles[J].Nano Letters,2004,4:191-195.
  • 5Florescu M,Christopher M A B.Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes[J].Talanta,2005,65:306-312.
  • 6Tsai Y C,Li S C,Chen J M.Cast thin film biosensor design based on a Nafion backbone,a multiwalled carbon nanotube conduit,and a glucose oxidase function[J].Langmuir,2005,21:3653-3658.
  • 7Wang L,Yuan Z B.Direct electrochemistry of glucose oxidase at a gold electrode modified with single-wall carbon nanotubes[J].Sensors,2003,3:544-554.
  • 8Cai C X,Chen J.Direct electron transfer of glucose oxidase promoted by carbon nanotubes[J].Analytical Biochemistry,2004,332:75-83.
  • 9Liu J Q,Chou A,Rahmat W,et al.Achieving direct electrical connection to glucose oxidase using aligned single walled carbon nanotube arrays[J].Electroanalysis,2005,17:38-46.
  • 10Rochette J F,Sacher E,Meunier M,et al.A mediatorless biosensor for putrescine using multiwalled carbon nanotubes[J].Analytical Biochemistry,2005,(366):305-311.