摘要 通过生物阻抗测量的研究来分析血液动力学。方法:对阻抗容积描记术原理深入研究与验证,提出阻抗容积描记术原理的改进。改进的阻抗容积描记术原理是利用悬浮物质电导率原理和泊萧叶流量定律,从而找出影响测量精度的干扰信号—呼吸波引起波动,从理论中找到了影响脉搏波阻抗测量的因素。试验的结果表明利用理论的成果和方法实现血液动力学参数较高精度的无创检测。 Bio-impedance measurement accuracy is difficult to improve because of individual variances, measuring conditions and many other factors. The paper suggests the project of improving impedance plethysmography, then utilizes the conductivity principle of suspending material and flux law of posieuille, at last achieves theoretically the factors that influence measurement accuracy of Bio-impedance. The experiments gain the accuracy hemodynamics parameters of non-invasive measurement with the theoretic result and method.
作者 刘胜洋
出处 《微计算机信息》 2011年第11期44-45,56,共3页 Control & Automation
基金 申请人:刘胜洋 项目名称:动态脉搏波阻抗谱测量血液成份的研究 基金颁发部门:安徽省教育厅自然科学研究(KJ2008B52)
关键词 脉搏波 动态阻抗 血液动力学 无创检测 Pulse Wave Dynamic impedance hemodynamics Non-invasive Measurement
  • 相关文献

参考文献11

  • 1任超世.医学电阻抗技术与临床.世界医疗器械,2003,9(2):50-53.
  • 250-53 .REN CHAO-Shi. Medical Electrical Impedance Technology and Breast Tumor Measurement,China Medical Devices Information.[J] 2003, Vol. 9(2): 50-53.
  • 3Min M, Parve T. An Electrical Bio-Impedance Analyzer for lmplantable Medical Devices Instrumentation and Measurement Technology Conference, 2005. IMTC [C] 2005. Proceedings of the IEEE Volume 3,16-19 May 2005.
  • 4Hollaus K, Biro O, Gerstenberger C, Preis K, Stollberger R, Wagner B. Effect of stray capacitances on bio-impedances in quasi-static electric field Magnetics, [J] IEEE Transaction on Volume 41, Issue 5, May 2005.
  • 5A. Caduff, E. Hirt, Yu. Feldman, Z. Ali, L. Heinemann. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system [J]. Biosensors and Bioelectronics. 2003(19): 209-217.
  • 6Yoshio Nikawa, Daisuke Someya. Application of Millimeter Waves to measure blood sugar level.[J] Proceedings of APM 2001, Taipei: 1303-1306.
  • 7李刚,卢宗武,刘胜洋,石艳丽.动态脉搏波阻抗谱理论分析与初步实验[J].天津大学学报,2007,40(10):1251-1255. 被引量:5
  • 8Lee E. Baker. Principles of impedance technique [J]. IEEE Engineering in Medicine and Biology Magazine. 1998(3): 11-15.
  • 9K. R.Visser, "Electric conductivity of stationary and flowing human blood at low frequencies," [J] Med. Biol. Eng. Comp, vol. 30, pp. 636 - 640, Nov. 1992.
  • 10Wtorek, J.; Polinski, A. "The contribution of blood-flow- induced conductivity changes to measured impedance" Biomedical Engineering[J], IEEE Transaction on Volume 52,Issue 1,?Jan. 2005.

二级参考文献17

  • 1Fatimah Ibrahim, Mohd Nasir Taib, A Novel Approach to Classify FeverUsing Bioelectrical Impedance Anasis [J]. IEEE TRANS ON INSTRMENT, 2005,54:237-244.
  • 2Rush,EC, Crowley,J, Freitas,IF. Validity of hand-to-foot measurement of bioimpedance: standing compared with lying position. Obesity research, 2006,14(2):252-257.
  • 3Stanley-AW,Jr, Herald,JW, Athanasuleas,CL. Multi-channel electrical bioimpedance: a new noninvasive method to simultane-ously measure cardiac and peripheral blood flow[J].Journal of clinical monitoring and computing, 2007,21(6):345-351.
  • 4任超世.医学电阻抗技术与临床.世界医疗器械,2003,9(2):50-53.
  • 5Min M,Parve T.An electrical bio-impedance analyzer for implantable medical devices[C]// Instrumentation and Measurement Technology Conference,2005 Proceedings of the IEEE.Ottawa,Canada:Instrumentation and Measurement Technology Society,2005:1823-1828.
  • 6Gergel A,Zlochiver S,Rosenfeld M,et al.Induced current bio-impedance technique for monitoring cryosurgery procedure in a two-dimensional head model using generalized coordinate systems[J].IEEE Transactions on Biomedical Engineering,2005,52 (7):1361-1365.
  • 7Hollaus K,Biro O,Gerstenberger C,et al.Effect of stray capacitances on bio-impedances in quasi-static electric field[J].IEEE Transactions on Magnetics,2005,41(5):1940-1943.
  • 8Caduff A,Hirt E,Feldman Y,et al.First human experiments with a novel non-invasive,non-optical continuous glucose monitoring system[J].Biosensors and Bioelectronics,2003 (19):209-217.
  • 9Elden Harry Richardson,Wicket Radall R.Method and Apparatus for Noninvasive Determination of Glucose in Body Fluids:US,US006517482[P].1999-04-06.
  • 10Nikawa Yoshio,Someya Daisuke.Application of millimeter waves to measure blood sugar level[C] //Proceedings of APMC 2001.Taipei,China,2001:1303-1306.

共引文献16

同被引文献57

引证文献4

二级引证文献18