期刊文献+

Anchor-wire technique for multiple plastic biliary stents to prevent stent dislocation

Anchor-wire technique for multiple plastic biliary stents to prevent stent dislocation
下载PDF
导出
摘要 In endoscopic placement of multiple plastic biliary stents (PBSs),we sometimes experience proximal dislocation of the first PBS at the time of subsequent PBS insertion.We describe the case of a 79-year-old male with obstructive jaundice caused by cholangiocarcinoma who needed to receive multiple PBS placements for management of cholangitis.Although proximal dislocation of the first PBS was observed,we prevented the dislocation via our technique of using guidewire inserted from the distal end of the first PBS to the side hole as the anchor-wire.We could complete this technique only by inserting guidewire through the side hole of the first PBS during the process of releasing the first PBS and pulling out the guidewire and the inner sheath.It did not matter whether the anchor-wire went towards the third portion of the duodenum or the duodenal bulb.Here we introduce this "anchor-wire technique",which is useful for the prevention of PBS proximal dislocation in placing multiple PBSs. In endoscopic placement of multiple plastic biliary stents (PBSs),we sometimes experience proximal dislocation of the first PBS at the time of subsequent PBS insertion.We describe the case of a 79-year-old male with obstructive jaundice caused by cholangiocarcinoma who needed to receive multiple PBS placements for management of cholangitis.Although proximal dislocation of the first PBS was observed,we prevented the dislocation via our technique of using guidewire inserted from the distal end of the first PBS to the side hole as the anchor-wire.We could complete this technique only by inserting guidewire through the side hole of the first PBS during the process of releasing the first PBS and pulling out the guidewire and the inner sheath.It did not matter whether the anchor-wire went towards the third portion of the duodenum or the duodenal bulb.Here we introduce this "anchor-wire technique",which is useful for the prevention of PBS proximal dislocation in placing multiple PBSs.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第28期3366-3368,共3页 世界胃肠病学杂志(英文版)
关键词 技术 支架 错位 胆道 塑料 PBS 十二指肠 Plastic biliary stent Anchor-wire technique Proximal dislocation Prevention Endoscopic retrograde cholangiography
  • 相关文献

参考文献8

  • 1Chang WH, Kortan P, Haber GB. Outcome in patients with bifurcation tumors who undergo unilateral versus bilateral hepatic duct drainage. Gastrointest Endosc 1998; 47:354-362.
  • 2Draganov P, Hoffman B, Marsh W, Cotton P, Cunningham J. Long-term outcome in patients with benign biliary strictures treated endoscopically with multiple stents. Gastrointest En- dosc 2002; 55:680-686.
  • 3Costamagna G, Pandolfi M, Mutignani M, Spada C, Perri V.Long-term results of endoscopic management of postopera- tive bile duct strictures with increasing numbers of stents. Gastrointest Endosc 2001; 54:162-168.
  • 4Chaurasia OP, Rauws EA, Fockens P, Huibregtse K. Endo- scopic techniques for retrieval of proximally migrated biliary stents: the Amsterdam experience. Gastrointest Endosc 1999; 50:780-785.
  • 5Katsinelos P, Kountouras J, Paroutoglou G, Chatzimav- roudis G, Paikos D, Zavos C, Karakousis K, Gelas G, Tzilves D. Migration of plastic biliary stents and endoscopic re- trieval: an experience of three referral centers. Surg Laparosc Endosc Percutan Tech 2009; 19:217-221.
  • 6Okabe Y, Tsuruta O, Kaji R, Ishida Y, Yasumoto M, Mit- suyama K, Suga H, Toyonaga A, Sata M. Endoscopic re- trieval of migrated plastic stent into bile duct or pancreatic loseudocvst. Di,~ Endosc 2009; 21:1-7.
  • 7Bismuth H, Castaing D, Traynor O. Resection or palliation: priority of surgery in the treatment of hilar cancer. World J Surg 1988; 12:39-47.
  • 8Pariak E, Cicek B, Koruk I, Disibeyaz S, Sahin B. Successful prevention of stent migration caused by placement of a sec- ond stent. Endoscopy 2005; 37:404.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部