期刊文献+

6038~6052cm^(-1)附近CH_4低温吸收光谱研究 被引量:1

Study of CH_4 Spectroscopy at Low Temperature Near 1.65 μm
下载PDF
导出
摘要 在CH4吸收光谱测量中,特别是低温吸收光谱测量中,分子吸收谱线的准确性测量十分重要,尤其是将所得的测量参数运用到地球大气以及外星球的遥感探测和模拟。HITRAN数据库中CH4给出的参数并不完整,同时还很不准确。为了对6 038~6 052cm-1波段的CH4低温吸收光谱进行测量,该文采用窄线宽的二极管激光器作为光源,结合自主设计的低温装置,测量了CH4的低能级能量和转动量子数,并与HITRAN 2008进行了对比,同时模拟了线强随温度的变化。 In the CH4 absorption spectroscopy measurement,especially the measurements at low temperature,the accurate values of the abs orption spectral parameters are very important.The absorption spectral paramete rs are especially important when the authors use parameters to sense and model t he atmospheres of the earth and the outer planets.Sometimes the CH4 parameter s listed in the HITRAN 2008 database are uncertain to some extent.In order to m easure the low temperature absorption spectroscopy of methane,the authors used a cryogenic cell newly developed by ourselves in combination with a distributed feedback(DFB) diode laser as the light source and measured the low stated energ y and the rotational angular momentum.And while the authors compared our data w ith HITRA N 2008,the authors modeled the line intensity changing with the temperature.Th e authors' measured parameters will be helpful for sensing and modelling the at mospheres of the earth and the outer planets.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2011年第12期3180-3184,共5页 Spectroscopy and Spectral Analysis
基金 中国科学院重大科研装备研制项目(YZ200818)资助
关键词 可调谐半导体激光吸收光谱 低温谱线 谱线强度 低能级能量 Tunable diode laser absorption spectroscopy Low temperature spectrum Line intensity Low stated energy
  • 相关文献

参考文献13

  • 1Muller G A. Contribution to the Implementation of the WMO Strategic Plan: 2008-2011 (WMO TD No. 1384). GAW Report, No. 172. World Meteorological Organization, Geneva, Switzerland, 2008.
  • 2Rothman L S, Gordon I E, et al. J. Quant. Spectrosc. Radiat. Transfer, 2009, 110: 533.
  • 3谷怀民,Alan Zhang.多光程吸收的频率调制光谱[J].光子学报,2003,32(8):1013-1016. 被引量:5
  • 4Boras K, Deboer D, Lin Z, et al. J. Chem. Phys. , 1993, 99: 1429.
  • 5Campargue A, Chenevier M, Stoeckel F. Chem. Phys. Lett. , 1991, 183: 153.
  • 6Campargue M, Permogorov D, Jost R. J. Chem. Phys. , 1995, 102: 5910.
  • 7Hippler M, Quack M. Chem. Phys. Lett. , 1999, 314: 273.
  • 8Hippler M, Quack M. J. Chem. Phys. , 2002, 116: 6045.
  • 9Amrein A, Quack M, Schmitt U. J. Phys. Chem. , 1988, 92: 5455.
  • 10Albert S, Bauerecker S, Boudon V, et al. Chemical Physics, 2009, 356: 131.

二级参考文献10

  • 1Nikkari Jason J, Di LorioJoannaM, Thomson Murray J. In situ combustion measurements of CO, H2O, and temperature with a 1. 58-microm diode laser and two-tone frequency modulation. Applied Optics ,2002 ,41 (3) : 446 ~ 452.
  • 2D'Amato F, De Rosa M. Tunable diode lasers and two-tone frequency modulation spectroscopy applied to atmospheric gas analysis. Optics and Lasers in Engineering, 2002, 37(5) : 533 -551.
  • 3Durry Georges, Danguy Theodore, Pouchet Ivan. Open multipass absorption cell for in situ monitoring of stratospheric trace gas with telecommunication laser diodes. Applied Optics, 2002,41(3) :424 -433.
  • 4Modugno G, Corsi C, Gabrysch M ,et al. Fundamental noise sources in a highsensitivity two-tone frequency modulation spectrometer and detection of CO2 at 1.6 μm and 2 μm. Appl Phys(B), 1998,67(3): 289-296.
  • 5Riffs H, Carlisle C B, Warren R E, et al. Signal-to-noise ratio enhancement in frequency modulation spectrometers by digital signal processing. Opt Lett, 1994,19(2) :144 ~ 146.
  • 6Chemin S M. New generation of muhipass systems in high resolution spectroscopy. Spectrochimica Acta Part A:Molecular Spectroscopy, 1996,52 ( 8 ) : 1009 ~ 1022.
  • 7Perry R, Klee * S, Lock M, et al. Spherical mirror multipass system for FHR jet spectroscopy: application to the rovibrationally resolved spectrum of OC5O. Journal of Molecular Structure, 2002,612(2 -3) : 369 -381.
  • 8Busch K W,Brusch M A( F_Ms, Baylor University). Cawityringdown spectroscopy - An ultratrace-absorption measurement technique. ACS Symposium Series No. 720,American Chemical Society, Washington, DC, 1999.
  • 9Hall G E, North S W. Transient laser frequency modulation spectroscopy. Anauai Review of Physical Chemistry, 2000,51(1) : 243 -274.
  • 10Steimle T C, Costen M L, Hall G E, et al. Transient frequency modulation absorption spectroscopy of molecules produced in a laser ablation supersonic expansion source.Chem Phys Lett, 2000,319(3-4) : 363 ~367.

共引文献4

引证文献1

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部