期刊文献+

莱钢3~# 1080m^3高炉炉缸更换冷却壁实践

Replacing Practice of the Hearth Cooling Staves in Laiwu Steel's No.3 1080m^3 BF
下载PDF
导出
摘要 为解决莱钢3#1080m3高炉铁口区门型冷却壁漏水情况,2011年3月采用焖炉方式进行年修,通过利用合理的冷却壁拆除、安装和密封方案及炉缸保水冷却、实时测温手段,成功更换了铁口区冷却壁和炉皮,消除了炉缸烧穿的隐患。 In order to solve the water leakage situation of the door-type cooling staves in the taphole zone of Laiwu Steel's No.3 1 080 m3 BF,annual overhaul by banking manner was made in March 2011. Through the use of reasonable cooling walls demolished,installation and sealing solutions,and implementation of the hearth cooling,real-time temperature measurement means,the iron notch cooling walls and shell of blast furnace were successfully replaced. After replacement,the overall effect was good,eliminating the accident potential of the hearth breakout.
出处 《山东冶金》 CAS 2011年第5期69-70,共2页 Shandong Metallurgy
关键词 高炉 冷却壁 炉缸 灌浆 blast furnace cooling staves hearth grouting