期刊文献+

生化废水COD的近红外光谱法测定 被引量:5

Determination of COD in Biological and Chemical Wastewater by Near Infrared Spectrometry
原文传递
导出
摘要 采用近红外光谱测定在紫外光谱区表现为弱吸收响应的生化废水的化学需氧量(COD)。通过主成分分析-欧氏空间距离类聚法筛选出具有代表性的样本,从系统独立变量数的角度判断了主成分数,结合变量标准化-基线扣除的预处理方法消除光谱信号背景干扰,建立了偏最小二乘校正模型。在系统主成分数为6时,水样的COD实测值与预测值之间的相关系数为0.9348,预测标准差(RM SEC)为61.89m g/L,模型有较好的预测能力。 The COD in biological and chemical wastewater that performed to weak absorption in the UV spectral region was determined by NIR spectrometry.Principal component analysis-Euclidean distance cluster was applied to select the representative sample.From the aspect of the number of independent variables,the number of principal components was determined.Combined with the SNV-Detrending preprocessing,the background signal of spectra was eliminated.The partial least squares model was built and the predictions were satisfied.When main component in the system amounted to 6,the linear correlation coefficient of measured values and predicted values was 0.9348 and the RMSEC was 61.89mg/L,the model had a better predictive ability.
出处 《光谱实验室》 CAS CSCD 北大核心 2011年第6期3040-3043,共4页 Chinese Journal of Spectroscopy Laboratory
基金 广西自然科学基金资助项目(桂科自0832064) 广西教育厅桂教科研资助项目(200708MS067)
关键词 化学需氧量 近红外光谱 偏最小二乘法 Chemical Oxygen Demand Near-Infrared Spectrometry PLS
  • 相关文献

参考文献4

二级参考文献11

  • 1史永刚.回荡式水中油萃取装置[P].中国新型实用专利ZL:02276574.3.2003—09—17.
  • 2Carduner KR,Marano RS,Eihrt AJ.Determination of Oil Concentration in Soluble Oil Cutting Fluids using Near—Infrared Spectroscopy[J].Process Control and Quality.1992,(2),143—154.
  • 3WILLIAMS P,NORRIS K.Near-Infrared technology in the agricultural and food industries.[M].Second ed.St.Paul,Minnesota:American Association of Cereal Chemists,Inc,2001.
  • 4MOLT K,NIEMOLLER A,CHO Y J.Analysis of aqueous solutions by near-infrared spectrometry (NIRS) Ⅱ.Titrations of weak and very weak acids with strong bases[J].Journal of Molecular Structure,1997,410-411:565-572.
  • 5FROST V J,MOLT K.Analysis of aqueous solutions by near-infrared spectrometry (NIRS) Ⅲ.Binary mixtures of inorganic salts in water[J].Journal of Molecular Structure,1997,410-411:573-579.
  • 6BERENTSEN S,STOLZ T,MOLT K.Analysis of aqueous solutions by near-infrared spectrometry (NIRS) IV.One-and two-component systems of organic compounds in water[J].Journal of Molecular Structure,1997,410-411:581-585.
  • 7KORSMAN T,NILSSON M,OHMAN J,et al.Near-infrared reflectance spectroscopy of sediments:A potential method to infer the past pH of lakes[J].Environ Sci Technol,1992,26:122-2126.
  • 8MOLT K,CHO Y J.Analysis of aqueous solutions by Near-Infrared Spectrometry (NIRS).I.Titrations of strong acids with strong bases[J].Journal of Molecular Structure,1995,349:345-348.
  • 9王光辉,梁玉河,胡霞,刘国琴,刘智平,靳美程,肖爱国,杜功柳.紫外分光光度法快速测定废水中COD的研究[J].燃料与化工,2000,31(1):31-33. 被引量:12
  • 10袁丽水.污水紫外吸光度与COD的关系[J].上海环境科学,2000,19(12):579-581. 被引量:18