期刊文献+

Prevention of No-flow With Distal Protection Device in Patients Underwent Percutaneous Coronary Intervention

Prevention of No-flow With Distal Protection Device in Patients Underwent Percutaneous Coronary Intervention
原文传递
导出
摘要 Objectives To evaluate the feasibility and safety of distal protection device (PercuSurge) during percutaneous coronary intervention (PCI) in patients with acute coronary syndrome. Methods From October 2004 to August 2007, 40 patients with high risk acute coronary syndrome who received primary coronary intervention were included in this study. Patients were divided into two groups according to whether PercuSurge was attempted during PCI. The basic clinical characteristics, angiographic results, and follow-up data before discharge were compared. Coronary arteries blood flow thrombolysis in myocardial infarction (TIMI) grade, TIMI myocardial perfusion (TMP) grade and the rate of no-reflow were performed in all cases after PCI. Results There was no significant difference between the two groups in basic clinical characteristics and angiography before PCI (P>0.05). All patients underwent PCI successfully in both groups. In the PercuSurge group, PCI with PercuSurge guardwire protection was performed successfully in 18 patients. There was significant difference between the two groups in TIMI 3 flows gained in target vessels after PCI. Better percentage of TMP grade 3 of target vessels was achieved in PercuSurge group. Less no-reflow were found in PercuSurge group. There were lower peak troponin I and serum MB isoenzyme of creatine kinase levels, higher left ventricular ejection fraction and smaller left ventricular end-diastolic dimension in the PercuSurge group after PCI at the date before discharge (P<0.05). There was no major adverse cardiac events in PercuSurge group, only one patient died in the control group. Conclusions This study demonstrates that using the PercuSurge Guardwire system during PCI in high risk acute coronary syndrome patients to prevent no-reflow is feasibility and safety. Objectives To evaluate the feasibility and safety of distal protection device (PercuSurge) during percutaneous coronary intervention (PCI) in patients with acute coronary syndrome. Methods From October 2004 to August 2007, 40 patients with high risk acute coronary syndrome who received primary coronary intervention were included in this study. Patients were divided into two groups according to whether PercuSurge was attempted during PCI. The basic clinical characteristics, angiographic results, and follow-up data before discharge were compared. Coronary arteries blood flow thrombolysis in myocardial infarction (TIMI) grade, TIMI myocardial perfusion (TMP) grade and the rate of no-reflow were performed in all cases after PCI. Results There was no significant difference between the two groups in basic clinical characteristics and angiography before PCI (P>0.05). All patients underwent PCI successfully in both groups. In the PercuSurge group, PCI with PercuSurge guardwire protection was performed successfully in 18 patients. There was significant difference between the two groups in TIMI 3 flows gained in target vessels after PCI. Better percentage of TMP grade 3 of target vessels was achieved in PercuSurge group. Less no-reflow were found in PercuSurge group. There were lower peak troponin I and serum MB isoenzyme of creatine kinase levels, higher left ventricular ejection fraction and smaller left ventricular end-diastolic dimension in the PercuSurge group after PCI at the date before discharge (P<0.05). There was no major adverse cardiac events in PercuSurge group, only one patient died in the control group. Conclusions This study demonstrates that using the PercuSurge Guardwire system during PCI in high risk acute coronary syndrome patients to prevent no-reflow is feasibility and safety.
出处 《South China Journal of Cardiology》 CAS 2008年第4期175-178,共4页 岭南心血管病杂志(英文版)
关键词 acute coronary syndrome ANGIOPLASTY distal protection device acute coronary syndrome angioplasty distal protection device
  • 相关文献

参考文献9

  • 1Gibson CM,Cannon CP,Murphy SA,et al.Relationship of TIMI myocardial perfusion grade to mortality after administration of thrombolytic drugs. Circulation . 2000
  • 2Davies MJ.The pathophysiology of acute coronary syndromes. Heart . 2000
  • 3Piana RN,Paik GY,Moscucci M,et al.Incidence and treatmentof“no-reflow”after percutaneous coronary intervention. Circulation . 1994
  • 4Yamada DM,Topol EJ.Importance of microembolization and inflammation in atherosclerotic heart disease. American Heart Journal . 2000
  • 5Kotani J,Nanto S,Mintz GS,et al.Plaque gruel of atheromatous coronary lesion may contribute to the no reflow phenomenon in patients with acute coronary syndrome. Circulation . 2002
  • 6Abbo KM,Dooris M,Glazier S,et al.Features and outcome of noreflow after percutaneous coronary intervention. The American Journal of Cardiology . 1995
  • 7Baim DS,Wahr D,George B,et al.Saphenous vein graft Angioplasty Free of Emboli Randomized (SAFER) Trial Investigators.Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation . 2002
  • 8Stone GW,Webb J,Cox DA,et al.Distal microcirculatory protection during percutaneous coronaryinterventionin acute ST-segment elevation myocardial infarction:a randomized controlledtrial. The Journal of The American Medical Association . 2005
  • 9Neumann FJ,Blasini R,Schmitt C,et al.Effect of glycoprotein Ⅱb/Ⅲa receptor blockade on recovery of coronary flow and left ventricular function after the placement of coronary-artery stents in acute myocardial infarction. Circulation . 1998

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部