摘要
以某小区消防给水设计为例,结合有关规范论述了屋顶消防水箱容积的确定,地下消防水池取水口的设置,室外消火栓和水泵接合器的设置,倒流防止器的设置.
Based on the defign of Fireproof water supply in a high-rise residential District,this paper discussed the mearsure of the volume of fireproof water tanks in the roof,setting of the underground water intake,settings of outdoor fire hydrant and pump adapter,and settings of backflowpreventer.
出处
《邵阳学院学报(自然科学版)》
2008年第4期90-91,共2页
Journal of Shaoyang University:Natural Science Edition
关键词
屋顶消防水箱
容积
地下消防水池取水口
室外消火栓
水泵接合器
倒流防止器
fireproof wanter tank in roof
volume
water intake of underground fireproof pool
outdoor fire hydrant
pump adapter
backflowpreventer