期刊文献+

袋装血液保存液中易氧化物的GC-MS分析 被引量:3

Analysis of the Reducing Substances Released from Blood Bags to Anticoagulant
下载PDF
导出
摘要 A method was established for determination of the reducing substances released from plastic blood bags to anticoagulant.The samples were extracted with a solid-phase extraction procedure using dichloromethane as extract solvents.The extracts were measured with GC-MS.Several reducing substances,such as 1,2-benzenedicarboxylic acid,alkane and bis(2-ethylhexyl) phthalate,etc were found in anticoagulant.The method was simple and can be used for the quality control of plastic blood bags. A method was established for determination of the reducing substances released from plastic blood bags to anticoagulant.The samples were extracted with a solid-phase extraction procedure using dichloromethane as extract solvents.The extracts were measured with GC-MS.Several reducing substances,such as 1,2-benzenedicarboxylic acid,alkane and bis(2-ethylhexyl) phthalate,etc were found in anticoagulant.The method was simple and can be used for the quality control of plastic blood bags.
出处 《分析测试学报》 CAS CSCD 北大核心 2008年第S1期271-273,共3页 Journal of Instrumental Analysis
关键词 SOLID-PHASE extraction GC-MS plastic BLOOD BAGS ANTICOAGULANT solid-phase extraction GC-MS plastic blood bags anticoagulant
  • 相关文献

参考文献6

  • 1Jimenez A,Lopez J,Vilaplana J,et al.Thermal degradation of plastisols.Effect of some additives on the evolution of gaseous products. J of Analytical and Applied Pyrolysis . 1997
  • 2Minna Hakkarainen.New PVC materials for medical applica-tions-the release profile of PVC/polycaprolactone-polycarbo-nate aged in aqueous environments. Polymer Degradation and Stability . 2003
  • 3Koichi Inoue Migaku Kawaguchi Retsuji Yamanaka Tae Higuchi Rie Ito Koichi Saito and Hiroyuki Nakazawa.Evaluation and analysis of exposure levels of di(2-ethylhexyl) phthalate from blood bags. Clinica Chimica Acta . 2005
  • 4ITO R,SESHIMO F,HAISHIMA Y,et al.Reducing the migration of di-2-ethylhexyl phthalate from polyvinylchloride medical devices. International Journal of Pharmaceutics . 2005
  • 5Hill S S,Shaw B R,Wu A H B.The clinical effects of plasti-cizers,antioxidants and other contaminants in medical poly-vinylchloride tubing during respiratory and non-respiratory exposure. Clinica Chimica Acta . 2001
  • 6Inoue K,Okumura H,Higuchi T,et al.Characterization of es-trogenic compounds in medical polyvinyl chloride tubing by gas chromatography-mass spectrometry and estrogen receptor binding assay. Clinica Chimica Acta . 2002