期刊文献+

Geometrical Reconstruction and CNC Process of Spurious Tympanic Membrane Based on Reverse Engineering 被引量:1

Geometrical Reconstruction and CNC Process of Spurious Tympanic Membrane Based on Reverse Engineering
下载PDF
导出
摘要 Perforation of tympanic membrane is one of the main reasons for both deafness and dyssaudia.We could improve and restore audition by restoring or replacing the tympanic membrane.So,whether you can make the spurious tympanic membrane successfully is one of the keys to a successful operation.Utilizing CMM (Coordinate Measuring Machine) measurement equipment, we measured tympanic membrane model precisely and digitally.We also analysed the measured data by point to surface and we have successfully reconstructed the CAD model of the spurious tympanic membrane.Using the model we have got,we schemed out the mold of spurious tympanic membrane.In addition,we utilized MasterCAM compiling CNC (Computerized Numerical Con- trol) code and simulating the course of working.Ultimately,we obtained the mold of spurious tympanic membrane.Our research in this article has great significance to the success of spurious tympanic membrane grafting operation. Perforation of tympanic membrane is one of the main reasons for both deafness and dyssaudia.We could improve and restore audition by restoring or replacing the tympanic membrane.So,whether you can make the spurious tympanic membrane successfully is one of the keys to a successful operation.Utilizing CMM (Coordinate Measuring Machine) measurement equipment, we measured tympanic membrane model precisely and digitally.We also analysed the measured data by point to surface and we have successfully reconstructed the CAD model of the spurious tympanic membrane.Using the model we have got,we schemed out the mold of spurious tympanic membrane.In addition,we utilized MasterCAM compiling CNC (Computerized Numerical Con- trol) code and simulating the course of working.Ultimately,we obtained the mold of spurious tympanic membrane.Our research in this article has great significance to the success of spurious tympanic membrane grafting operation.
出处 《武汉理工大学学报》 CAS CSCD 北大核心 2006年第S2期592-595,共4页 Journal of Wuhan University of Technology
关键词 REVERSE engineering SPURIOUS tympanic membrane GEOMETRICAL RECONSTRUCTION CNC process reverse engineering spurious tympanic membrane geometrical reconstruction CNC process
  • 相关文献

同被引文献2

引证文献1

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部