期刊文献+

Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS 被引量:15

Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
原文传递
导出
摘要 For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets’ spectrum acquired from different dates and different places would like to be consistent to each other within 1%―5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations. For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets’ spectrum acquired from different dates and different places would like to be consistent to each other within 1%―5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2005年第S2期44-60,共17页 中国科学(技术科学英文版)
关键词 CBERS-02 CCD camera CROSS-CALIBRATION the spectral BAND MATCHING factors. CBERS-02, CCD camera, cross-calibration, the spectral band matching factors.
  • 相关文献

参考文献3

  • 1Tong,J. J.The study on synthesis radiometric calibration methods for satellite sensors[]..2004
  • 2Loeb,N. G.In-Flight calibration of NOAA AVHRR visible and near-IR bands over Greenland and Antarc- tica[].International Journal of Remote Sensing.1997
  • 3Richter,R.On the in-flight absolute calibration of high spatial resolution spaceborne sensors using small ground targets[].International Journal of Remote Sensing.1997