摘要
The organic phase extracted from interfacial crud of copper solvent extraction at Dexing Copper Mine was analyzed for its different components by combined gas chromatography mass spectroscopy. It was found that the main impurities in organic phase were methylnaphthalenes and di methylnaphthalenes which originated from commercial 260# kerosene used as diluent. It was found that the impurities containing diluent was unfavorable to phase disengagement. Methods were suggested to improve diluent properties to prevent stable interfacial emulsion.
The organic phase extracted from interfacial crud of copper solvent extraction at Dexing Copper Mine was analyzed for its different components by combined gas chromatography mass spectroscopy. It was found that the main impurities in organic phase were methylnaphthalenes and di methylnaphthalenes which originated from commercial 260# kerosene used as diluent. It was found that the impurities containing diluent was unfavorable to phase disengagement. Methods were suggested to improve diluent properties to prevent stable interfacial emulsion.
出处
《中国有色金属学会会刊:英文版》
CSCD
2000年第S1期97-100,共4页
Transactions of Nonferrous Metals Society of China
基金
Project 5 992 5 412supportedbytheNationalScienceFoundationforDistinguishedYoungScholarsandProject 970 5 330 8sup portedbyDocto