期刊文献+

In-situ pH Measurement at the Electrode/Solution Interface

In-situ pH Measurement at the Electrode/Solution Interface
下载PDF
导出
摘要 In this paper a pH microprobe technique was developed to measure in-situ the pH value at the electrode/solution interface. Iridium oxide was used as a pH sensitive material with good response behavior in the measured solutions. The experimental results indicated that the interfacial pH increased with the applied potential, first jumped to a maximum, then slowly decreased at the controlled potential during the electrodeposition process of functional ceramics. In this paper a pH microprobe technique was developed to measure in-situ the pH value at the electrode/solution interface. Iridium oxide was used as a pH sensitive material with good response behavior in the measured solutions. The experimental results indicated that the interfacial pH increased with the applied potential, first jumped to a maximum, then slowly decreased at the controlled potential during the electrodeposition process of functional ceramics.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第7期617-620,共4页 中国化学快报(英文版)
关键词 in-situ measurement pH microprobe electrode/solution interface in-situ measurement pH microprobe electrode/solution interface
  • 相关文献

参考文献5

  • 1M SHIRKHANZADEH.Direct formation of nanophase hydroxyapatite on cathodically polarized electrodes[J].Journal of Materials Science: Materials in Medicine.1998(2)
  • 2J. M. Zhang,C. J. Lin,Z. D. Feng,et al.J Mater Sci[].Lett.1998
  • 3J. M. Zhang,C. J. Lin,Z. D. Feng,et al,Chem. J Chinese Universities . 1997
  • 4L. Gal-Or,I. Silberman,R Chain,J Electrochem. Society . 1991
  • 5C. J. Lin,J. L. Luo,H. Y. Sun,et al. Electrochemistry . 1996

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...