期刊文献+

Study on the Flow Injection Micro-Column Pre-Separation System Coupled With High Performance Liquid Chromatography for the Determination of Ecdysterone in Traditional Chinese Medicine

Study on the Flow Injection Micro-Column Pre-Separation System Coupled With High Performance Liquid Chromatography for the Determination of Ecdysterone in Traditional Chinese Medicine
下载PDF
导出
摘要 A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk. A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk.
出处 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期83-88,共6页 武汉大学学报(自然科学英文版)
基金 Education Ministy Foundation for Chinese Returned Scholars and Nature Science Foundation of Hubeiprovince!98J054
关键词 high performance liquid chromatography(HPLC) Flow injection analysis (FIA) ECDYSTERONE traditional Chinese medicine high performance liquid chromatography(HPLC) Flow injection analysis (FIA) ecdysterone traditional Chinese medicine
  • 相关文献

参考文献14

  • 1M. Báthori,K. Szendrei,I. Herke.Application of combined chromatographic techniques in the screening and purification of ecdysteroids[J]. Chromatographia . 1986 (4)
  • 2ZHANG Z,YANG M L,PAWLISZYN J.Solidphase Microextraction. Analytical Chemistry . 1994
  • 3WANG X R,BARNES R M.Chelating Resins forOn-line Flow Injection Pre-concentration With Inductively Coupled Plasma Atomic Emission Spectrometry. Journal of Analytical Atomic Spectrometry . 1989
  • 4GUO D A,LOU Z Q.Separation and QuantitativeDetermination of Three Phytoecdysteroids in Rhapontium Uniflorum by High Performance Liquid Chromatograghy. Journal of Chinese Pharmaceutical Sciences . 1992
  • 5ZHANG Z,PAWLISZYN J.Quantitative ExtractionUsing an Internally Cooled Solid Phase Microextraction Device. Analytical Chemistry . 1995
  • 6SPERLING M,XU S K,WELZ B.Determination ofchromium (III) and chromium (VI ) in Water UsingFlow injection On-line Preconcentration With Selective Adsorption on Activated Alumina and FlameAtomic Absorption Spectrometric Detection. Analytical Chemistry . 1992
  • 7PAWLISZYN J.New Directions in Sample Preparation for Analysis of Organic Compounds. TrAC Trends in Analytical Chemistry . 1995
  • 8FANG Z L,SPERLING M,WELZ B.Flow Injectionon-line Sorbent Extraction Pre-concentration forGraphite Furnace Atomic Absorption Spectrometry. Journal of Analytical Atomic Spectrometry . 1990
  • 9HAWTHORNE S B.Analytical--scale SupercriticalFluid Extraction. Analytical Chemistry . 1990
  • 10WILSON I D.Thin--layer Chromatography of Ecdysteroids. Journal of Chromatography . 1985