摘要
利用原子吸收光度法连续测定渣样中的Mg、Mn、Pb、Zn、Cu、K、Na、Li含量,称样、溶样只需一次,就可完成8种元素的连续测定。该方法操作简便、快速,而且测定结果准确可靠,测定各元素的相对标准偏差为0.3%~25%,回收率达97%~102%。
Through once weighing sample and dissolving sample , the elements of Mg , Mn, Pb, Zn , Cu, K, Na , Li can be determined continuously in slag sample used of atomic absorption photometry. The feature of this method is convenient operation,determining accuracy. The relative error of determined elements is 0.3% ~ 2.5%, the recovery ratio is up to above 97% -102%.
出处
《山东冶金》
CAS
1999年第S1期133-134,共2页
Shandong Metallurgy
关键词
原子吸收光度法
元素测定
渣样分析
atomic absorption photometry, element determination, slag sample analysis