本文介绍了几种泵站铅酸蓄电池容量的计算方法,阐述了中小型泵站铅酸蓄电池容量选择宜根据其直流负荷的特点,采用传统方法计算确定,并通过用不同方法计算所得的结果进行比较,说明用传统方法的合理性与经济性。
Several kinds of methods for calculating the storage capacity of lead-acid battery are introduced,the writers hold the storage capacity of battery of medium and small-typed pumping station should be determined with traditional method according to the feature of direct current charge.
出处
《山西水利科技》
1999年第S1期80-81,共2页
Shanxi Hydrotechnics
关键词
中小型泵站
铅酸蓄电池
容量计算
直流负荷
Medium and Small Pumping Station Lead-acid Battery Storage Capacity