期刊文献+

Efficiency of Superfine Glass Fiber Membrane Filters for Depleting Leukocytes

Efficiency of Superfine Glass Fiber Membrane\= Filters for Depleting Leukocytes
下载PDF
导出
摘要 Leukocyteremovalfilters made of superfine glass fiber membranes for depleting leukocytes in red cell suspensions to prevent nonhemolytic transfusion reactions were investigated. The performance evaluation of such filters was based on the detection of leukocyte depletion rate and red cell recovery rate. Residual leukocytes after filtration were counted in a 50 l Nageotte counting chamber. The chemical stability of the glass fiber membranes was studied by plasma emission spectrometer and by measuring the ion content and weighing nonvolatile matter in water extract. The structural stability of the glass fiber membranes was studied by micropore filter membrane method. The results showed that glass fiber membrane filters could deplete more than 99.0% of leukocytes in the red cell suspension prepared from 400 ml whole blood. The total number of residual leukocytes was less than 510\+6. The water extract of the glass fiber membranes contained only few Si\+\{4+\} and Ca\+\{2+\} and less than 2 mg/100 ml o f nonvolatile matter. No broken or loose fibers were found in the filters. Scanning electron microscopy (SEM) showed that the structure of the glass fiber membranes was instrumental in holding and trapping leukocytes. Leukocyteremovalfilters made of superfine glass fiber membranes for depleting leukocytes in red cell suspensions to prevent nonhemolytic transfusion reactions were investigated. The performance evaluation of such filters was based on the detection of leukocyte depletion rate and red cell recovery rate. Residual leukocytes after filtration were counted in a 50 l Nageotte counting chamber. The chemical stability of the glass fiber membranes was studied by plasma emission spectrometer and by measuring the ion content and weighing nonvolatile matter in water extract. The structural stability of the glass fiber membranes was studied by micropore filter membrane method. The results showed that glass fiber membrane filters could deplete more than 99.0% of leukocytes in the red cell suspension prepared from 400 ml whole blood. The total number of residual leukocytes was less than 510\+6. The water extract of the glass fiber membranes contained only few Si\+\{4+\} and Ca\+\{2+\} and less than 2 mg/100 ml o f nonvolatile matter. No broken or loose fibers were found in the filters. Scanning electron microscopy (SEM) showed that the structure of the glass fiber membranes was instrumental in holding and trapping leukocytes.
出处 《The Journal of Biomedical Research》 CAS 1999年第1期42-46,共5页 生物医学研究杂志(英文版)
关键词 leukocyte depletion FILTRATION glass fiber membrane component transfusion leukocyte depletion filtration glass fiber membrane component transfusion
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部