摘要
介绍了汽车用液化石油气加气站的建设规模、单罐容量、工艺流程的确定,以及所采取的在常开管路上设紧急切断阀、设置可燃气体浓度检测及报警器等安全措施。
The determination of construction size, individual tank capacity and process flow of a LPG service sta-tion, and various safety considerations such as emergency block valve on normally open pipeline, flammable gas detec-tor and alarm device etc. are explained in this paper.
出处
《石油商技》
1999年第3期28-29,共2页
Petroleum Products Application Research
关键词
汽车
液化石油气
加气站
储罐
vehicle
LPG
service station
storage tank